User Manual
AS4000 Central Terminal
Installation and Commissioning
DLP 007
605-0000-452
Issue 1.3dr Date 7/02/00
Page 4 of 4
4. PSU Voltage Modem Shelves: (Test 2a)
Using the DMM, measure and record the DC voltage at the front panel test points on
each of the PSUs on the Modem Shelf.
Card Fail
PSU OK
I/P A Fail
I/P B Fail
O/P Overload
O/P Underload
0V
2.1V
3.3V
5V
Figure 29. Modem Shelf PSU
Ensure that the voltages measured are within the limit shown in Table 4. Record the
results in test form.
Voltage Upper Limit Lower Limit
5V DC 5.25V 4.75V
3.3V DC 3.0V 3.3V
2.1V DC 2.1V 2V
Table 4
STOP. THIS PROCEDURE HAS BEEN COMPLETED.