User Manual

AS4000 Central Terminal
Installation and Commissioning
DLP 002
605-0000-452
Issue 1.3dr Date 7/02/00
Page 1 of 4 © Copyright Airspan Communications Corporation 2000
RACK INSTALLATION
1. Positioning and Securing Racks
1.1. Rack Preparation
Important: If the installation consists of two racks (four modem shelves), or an
expansion rack is being installed to expand the capacity of an existing CT Rack, remove
the knock out panels from the side of the racks. Place the protection strip in the hole to
protect the inter-rack cabling. This operation cannot be done after the racks are
positioned together.
1.2. Installing Rack in a Suite
From the site survey, confirm the position of the CT Racks. If the racks are to be
positioned in a suite, metalwork will be required to secure it to the overhead structure.
Either a proprietary system or fabricated steelwork will be required - see site survey.
Manoeuvre the racks into position.
Hole for rack
connecting bolt
Hole for rack
connecting bolt
Hole for ducting
cables between racks
DA Rack
Expansion Rack
Figure 2. Central Terminal Racks.