User Manual

AS4000 Central Terminal
Installation and Commissioning
Appendix
605-0000-452
4
Issue 1.3dr Date 7/02/00
Page 1 of 6 © Copyright Airspan Communications Corporation 2000
Appendix 4
PROGRAMMING THE TEST ST-V2 CRU (TYPE 2 PSU AND
TYPE 4 PSU) USING A TEST TELEPHONE
The ST-V2 should be programmed prior to commissioning. This procedure should be used
if programming the system using a test telephone.
STEP PROCEDURE
1. ST Programming
1. Remove the cover from the PSU
2. Connect an MF or LD type telephone to the NTU
3. Each CRU is initialised by entering a unique code. These codes are entered using the
telephone and should be provided by the RF planning office on a form similar to that
shown in Table 7.
Table 7. CRU Programming Information
Mode
DA=1
RF
3 digits
PN
1 digit
Identity
9 digits
Check N
o
.
1 digit
Remote site
location
1 0 0 6 1 000000000 7 CRU1
4. To program the ST, depress the reset switch, (Type2 SW4, Type 4 SW2), in the PSU for
approximately 3 seconds. LED D8 will begin flashing to indicate the CRU initialising and
self test sequence. After approximately 10 sec, the CRU initialising and self test sequence
will be complete and the LED will be extinguished. LED D9 will still be illuminated.
5. Take phone off hook and key # * # using the DTMF keypad
6. Enter Mode by keying 1 for DA or 2 for FA
7. Enter RF code (3 digits)
8. Enter PN code
9. If the CRU is to be used in fixed assigned mode enter the RW code (2 digits)
10. Enter the identity (9 digits)
11. Use * to end programming
a) Enter check digit