PROCEDURE IN CASE OF CARD BOOT-UP FAILURE
1. Procedure in case of card boot-up failure
If the cards inserted into the shelf do not boot-up, the top red LED on the card will be either
continuously ON or FLASHING. The following steps should be followed:
1. Check cards are properly inserted into the shelf, in the correct positions.
2. Reset the SC card using Sitespan, under the card view.
If the card will still not boot-up, then it is necessary to try and reset the shelf backplane
configuration. In order to achieve this, a number of text files will be required to download to the
SC. Ensure they are available before continuing. The files required are as follows:
For the CT:-
SetTUinv.txt
Mdsetinv.txt
Ausetinv.txt
Now the following procedure can be followed:
1. Disconnect Sitespan from the shelf containing cards that will not boot-up.
2. Connect the LAT cable to the SC card
3. Send the text files for the correct shelf, one after another using Terminal.
4. Once completed, type the following:
TI 118
EA 118:0/119:0
ES 0
5. Wait 2 – 3 minutes for the process to complete.
6. Reset the SC by shorting Pins 2 & 3
7. Wait for 3 minutes
The result will be the SC with a green LED ON, and all the other cards with FLASHING red
LEDs
8. Re-Connect Sitespan
The cards on the shelf should now boot-up. If the cards will still not boot-up, then it is likely
that one of the cards is faulty. Try replacing the one of the cards and starting the procedure
again.