User Manual
AS4000 DA CT Commissioning Unit
Operators Manual
GSI 002
605-0000-455
Issue 2.0. Date 21/03/00
Page 14 of 28
5.2. RF Interconnect
The Commissioning Unit has two RF ports (SMA connectors 50 Ohm
impedance) the RF lead is connected to port A and to the RF antenna port
using one length of RF cable and one coupler per antenna port. Unused ports
are terminated using 50 ohm RF loads. All couplers and cables are marked to
show insertion loss.
DIP/LNA
J1
J2
J3
Antenna Feed
80 dB Coupler
SMA connector
N type connector
5.3. Power Meter Connections
The Power meter is connected to the transmit port (B) on the DACU
Dip/
LNA
TX
Filter
Left Side
AB