3. The downtilt angles are not marked by the adjustment slots so a tiltmeter is required to set a
specific angle and then tighten the flange nuts ith a 10mm wrench on each stud (4 positions)
Figure 13 Tighten flange nuts (4 poitions) once the required mounting angle is set
4. There is an option to connect an earthing cable to the M6 screw fixing point at the bottom of
the main body casting. This should be connected to a protection ground bar or directly to the
steel structure of the power or pole. This is only required in areas of high lightning activity or
when the AirSynergy unit is mounted on high exposed roofs or tower structures
5. Connect the earth cable to the protection earth bar using suitable crimp lugs. Alternatively
use a TK series clamp to join the earth cable to the steel structure of the mounting pole or
tower structure.
Figure 14 AirSynergy attach earth cable to pole