User's Manual
HiperMAX Masthead Equipment Installation Guide
Page 42 Commercial in Confidence UGD-D00093 Rev A.1
Read Write Community: This should be specified to the same value as in Netpans
Discovery Parameters (found under "Server" on Netspans left hand panel).
SNMP Port Number: This should be specified to the same value as in Netpans Discovery
Parameters (found under "Server" on Netspans left hand panel).
IP Address: This specifies Netspans IP address (found under Server Global Configuration,
which is under Server on Netspans left hand panel).
Community: Normally specified to the same value as for Read Only Community.
Port Number: Normally specified to a value of 9023.
Whether the Primary Master blade or the Secondary Master blade manages the GPS
module.
NTP configuration. This specifies a list of NTP servers.
9.2 Secure Fibre-optic Cable
The Milli-Tie can be used to secure cables in the same manner as normally used for nylon straps.
The steps below show the basic use of the product.
Over-tightening of cable ties may causes damage and degrade system
performance.
To secure fibre-optic cables, perform the following steps:
1. Place the Millie-Tie around the target, and thread the tongue through the last large aperture in
the rearmost cell.
Figure 26 – HiperMAX secure fibre-optic cable, place tie
2. Pull or slide the Millie-Tie onto the target. Note that the Millie Tie stretches to cushion the
installation.