User's Manual

3
MAINTENANCE
1.Removeendcap,exposing
theshuttle.
2.Makesuretheshuttleisinthe
valveopenposition.
3.DriptwodropsofAirsoft
InnovationsGrenadeOil.Try
todripoildirectlyintothegas
chamber.
x2
LubricateyourAIgrenadeonceeverytwodeploymentsto
maintaindelayconsistency.UseAIsuppliedGrenadeSilicone
Oil,otheroilsmayaffecttheconsistencyofyourgrenade.A
stiffshuttlethatisdifficulttoresetwhenreloadingisan
indicationthatyourgrenadeneedslubricant.
Do not apply lubricants into
the delay chamber. Contami-
nation of delay chamber can
adversely affect the consis-
tency of your grenade's delay.
WARNING
4
RELIEF VALVE RESET
1.Firmlygraspthetopofthe
over-pressurereliefvalve.
2.Gentlypullthereliefvalve
upwardsby1mmandease
thevalvebackdown.
3.Securelyreseatthereliefvalve
byapplyingalittledownwards
pressuretothetop.
Reliefvalve
YourAirsoftInnovationsTornadogrenadefeaturesseveral
safetymeasures.Ifyourgrenadereachesaninternalpressure
of170psi(propaneat~40°C),itwilltriggertheover-pressure
reliefvalveandsafelyreleaseexcesspressure.Fillingyour
grenadewithpropellantafterwardswillcauseasmallleak
unlessitisresetasshownbelow.Ifcorrectpropellantsare
used,youwillneverneedtoresetyourreliefvalve.
1. 2.
1mm
3.