Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: R4H4
428 65 6008 00 3
Specifications subject to change without notice.
PHYSICAL DATA
UNIT SIZE SERIES 18(A,G)KB 24(A,G)KB 30(A,G)KB 36(A,G)KB 42(A,G)KB 48(A,G)KB 60(A,G)KB
Compressor Type Scroll
REFRIGERANT R410A
Control TXV (R410A Hard Shutoff)
Charge lb (kg) 5.3 (2.4) 5.6 (2.5) 6.4 (2.9) 7.67 (3.48) 8.25 (3.74) 8.68 (3.94) 10.6 (4.81)
COND FAN Forward Swept or Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1700 2196 3365 1200 3800 3365 4050
Motor HP 1/12 1/10 1/4 1/5 1/4 1/4 1/4
Motor RPM 1100 1100 1100 1100 1100 1100 800
VALVE CONNECT. (In. ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES* (In. OD)
Rated Vapor 5/8 5/8 3/4 3/4 7/8 7/8 11/8
Max Liquid Line 3/8
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
ELECTRICAL DATA
UNIT SIZE V/PH
OPER VOLTS* COMPR FAN
MCA
MAX
FUSE** or
CKT BRK
AMPS
MAX MIN LRA RLA FLA
18
208/230/1 253 197
48.0 9.0 0.50 11.8 20
24 62.9 10.9 0.60 14.2 25
30 72.5 13.5 1.40 16.9 30
36 75.0 14.7 1.10 19.5 30
42 105.1 18.1 1.40 24.0 40
48 108.0 19.0 1.40 25.2 40
60 144.2 24.4 1.52 32.0 50
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C, consult table 31016 of the NEC (NFPA 70). The ampacity of nonmetallicsheathed cable (NM),
trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 33626. If other than uncoated (noplated), 60 or 75_C
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** TimeDelay fuse.
FLA Full Load Amps
LRA Locked Rotor Amps
MCA Minimum Circuit Amps
RLA Rated Load Amps
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
AWEIGHTED SOUND POWER
UNIT SIZE
STANDARD
RATING
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125 250 500 1000 2000 4000 8000
18 69 45 48 56 62 55 53 47
24 76 46 56 59 63 63 60 55
30 77 52 62 67 68 65 62 55
36 77 51 62 66 69 64 61 53
42 76 49 61 63 65 62 60 52
48 79 53 66 69 71 67 64 57
60 73 50 63 62 63 60 58 52
NOTE: Tested in accordance with AHRI Standard 27008 (not listed in AHRI).
AWEIGHTED SOUND POWER WITH SOUND HOOD
UNIT SIZE
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125 250 500 1000 2000 4000 8000
18 68 47 48 56 61 55 52 46
24 74 47 57 59 62 61 58 51
30 77 52 62 67 67 65 62 54
36 76 52 62 66 67 64 60 52
42 74 50 61 63 64 61 58 49
48 79 54 66 69 70 67 64 56
60 73 51 64 62 63 59 56 49
NOTE: Tested in accordance with AHRI Standard 27008 (not listed in AHRI).