Specifications

PRODUCT SPECIFICATIONS Gas Furnace: N80ESN, N80ESL
8 441 51 3400 04
Specifications subject to change without notice.
Venting Notes
1. For common vent, vent connector sizing and vent material, use the NFGC.
2. Immediately increase to 5 inch (127 mm) or 6 inch (152 mm) vent connector outside furnace casing when 5 inch (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
the Downflow Vent Guard Kit, is used in the downflow position
4. Type--B vent where required, refer to the Note 1 above.
5. A 4 inch (102 mm) single--wall (26 ga. minimum) vent must be used inside furnace casing and when the Downflow Vent Guard Kit
is used external to the furnace.
6. Accessory Downflow Vent Guard Kit is required in downflow installations with lower vent configuration.
7. Chimney Adapter Kit may be required for exterior masonry chimney applications. Refer to Chimney Adapter Kit for sizing and
complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, spaced approximately 180 apart.
9. Secure all other single wall vent connector joints with (3) corrosion resistant screws spaced approximately 120 apart. Secure
Type--B vent connectors per vent connector manufacturer’s recommendations.
A
CCESSORIES
PART DESCRIPTION 0451412 0451712 0701412 0701712 0702116 0901714 0902116
NAHB00501FF
External Bottom Filter Rack, 14 inch
(14 x 25 inch washable filter included)
X
X
X
X
NAHB00601FF
External Bottom Filter Rack, 17 inch
(17 x 25 inch washable filter included)
X
X
NAHB00701FF
External Bottom Filter Rack, 21 inch
(20 x 25 inch washable filter included)
X
NAHA00506FB Washable filter, 1 inch 16 x 25 (6 pack)
X
X
X
X X
X
NAHA00706FB Washable filter, 1 inch 24 x 25 (6 pack)
X
NAHA01401RA Return
A
ir Kit, 14--3!6” Wide
X
X
NAHA01701RA Return
A
ir Kit, 17” Wide
X
X
X
NAHA02101RA Return
A
ir Kit, 21” Wide X
X
NAHA01101SB
Combustible Floor Base (Not required
when evaporator coil case is used for
downflow)
X
X
X
X X
X
X
NAHB00301VC
Downflow Vent Guard (Not required when
vent is routed through cabinet)
X
X
X
X X
X
X
NAHA00401DH Chimney
A
dapter Kit 4--in. vent
X
X
X
X X
X
X
A
GAGC8NPS01A Natural--to--Propane Conversion Kit
*
X
X
X
X X
X
X
A
GAGC8PNS01A Propane--to--Natural Conversion Kit
*
X
X
X
X X
X
X
A
GABLRJMP10A Blower Speed Tap Jumper Kit (10 pack)
X
X
X
X X
X
X
A
CCESSORIES
PART DESCRIPTION 0902120 0902420 1102120 1102420 1352420 1552420
NAHB00601FF
External Bottom Filter Rack, 17 inch (17
x
25 inch
washable filter included)
X
NAHB00701FF
External Bottom Filter Rack, 21 inch (20
x
25 inch
washable filter included)
X
X X
NAHB00801FF
External Bottom Filter Rack, 24 inch (24
x
25 inch
washable filter included)
X
X
NAHA00506FB Washable filter, 1 inch 16 x 25 (6 pack)
X
NAHA00706FB Washable filter, 1 inch 24 x 25 (6 pack)
X
X X
X
X
NAHA02101RA Return
A
ir Kit, 21” Wide
X
X
NAHA02401RA Return
A
ir Kit, 24” Wide
X
X
X
X
NAHA01101SB
Combustible Floor Base (Not required when
evaporator coil case is used for downflow)
X
X
X X
X
X
NAHB00301VC
Downflow Vent Guard (Not required when vent is
routed through cabinet)
X
X
X X
X
X
NAHA00401DH Chimney
A
dapter Kit 4--in. vent
X
X
X X
NAHA00301DH Chimney
A
dapter Kit 5--in. vent
X
X
A
GAGC8NPS01A Natural--to--Propane Conversion Kit
*
X
X
X X
X
X
A
GAGC8PNS01A Propane--to--Natural Conversion Kit
*
X
X
X X
X
X
A
GABLRJMP10A Blower Speed Tap Jumper Kit (10 pack)
X
X
X X
X
X
X Accessory available
Suitable for 17 inch external bottom filter rack
* Factory authorized and field installed. Gas conversion kits are CSA recognized.
Copyright 2019 International Comfort Products
Lewisburg, Tennessee 37091 USA
www.GoAirquest.com