Specification Sheet

2
518 71 2005 06
Specificatio ns subject to change without notice.
MODEL NUMBER NOMENCLATURE
MODEL NOMENCLATURE
MODEL SERIES
1 2 3 4 5,6 7,8,9 10 11,12 13 14 15
P H D 4 36 000 K 00 0 F 1
P = Package
H = Heat Pump
D = Standard
TIER
3=13
4=14
5=15
SEER
24 = 24,000 BTUH = 2 Tons
30 = 30,000 BTUH = 2.5 Tons
36 = 36,000 BTUH = 3 Tons
42 = 42,000 BTUH = 3.5 Tons
48 = 48,000 BTUH = 4 Tons
60 = 60,000 BTUH = 5 Tons
NOMINAL COOLING CAP ACITY
000 = no factory heat
NOMINAL HEATING BTUH (input)
K = 208/230 - 1- 60
H = 208/230 - 3- 60
L=460-3-60
VOLTAGE
00 = No options
TP = Tin- Plated Evaporator Main Tubes
LC = Low Cabinet Air Leakage plus Tin- Plated Copper Evap Main Tubes
F ACTORY INSTALLED OPTIONS
0 = Standard
FEATURE CODE
Sales Model Digit
Engineering Digit
AHRI* CAPACITIES
COOLING CAPACITIES AND EFFICIENCIES
UNIT NOMINAL TONS STANDARD CFM COOLING CAPACITY EER SEER
24 2 800 23000 12.0 14.5
30 2.5 1000 28600 11.5 14.0
36 3 1200 34200 11.5 14.0
42 3.5 1400 41000 11.5 14.0
48 4 1600 48000 12.0 14.0
60 5 1750 57500 11.5 14.0
HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES
UNIT
HEATING CAPACITY (BTUH) @
47° F (8.3° C)
COP @ 47° F
(8. C )
HEATING CAPACITY (BTUH) @
17° F (-8. C)
COP @ 17° F
(-8.3° C)
HSPF
24 22600 3.7 12000 2.30 8.0
30 28400 3.7 15600 2.35 8.0
36 34400 3.6 18600 2.30 8.0
42 40000 3.6 22600 2.40 8.0
48 46000 3.6 25800 2.40 8.0
60 57500 3.7 33000 2.45 8.0
LEGEND
dB- Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
COP- Coefficient of Performance
HSPF- Heating Season Performance Factor
* Air Conditioning, Heating & Refrigeration Institute.
**At A” conditions- 80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb & 95_F
(35_C) outdoor db.
{ Rated in accordance with U.S. Government DOE Department of Energy) test
procedures and/or AHRI Standards 210/240.
Notes:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80F (26.7_C) db, 67F (19.4_C) wb indoor entering- air
temperature and 95F(35_C) db outdoor entering- air temperature.
2. Before purchasing this appliance, read important energy cost and efficiency
information available from your retailer.