Specification Sheet

Use of the AHRI Certified TM Mark in-
dicates a manufacturer’s participation
in the program. For verification of certi-
fication for individual products, go to
www.ahridirectory.org .
Specifications subject to c hange without notice.
51871200506 9/15/18
Up to 14.5 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS
208/230- 1- 60 Single Phase 2- 5 Nominal Tons (Sizes 24- 60)
208/230- 3- 60 & 460- 3- 60 Three Phase, 3- 5 Nominal Tons (Sizes 36- 60)
REFRIGERATION CIRCUIT
Environmentally balanced R- 410A refrigerant
Copper tube/aluminum fin condenser and evaporator coils
Scroll compressor standard on all models
Short- cycling protection for the compressor is built into the defrost control board
Dehumidification mode (airflow reduction) on all models
EASY TO INSTALL AND SERVICE
Installs easily on a rooftop or at ground level
Easy three- panel accessibility for maintenance and installation
Easily converts to down discharge applications
Combination electric heating and cooling
BUILT TO LAST
Direct drive high efficiency ECM blower motor on all models
Pre- painted steel cabinet
Vertical condenser fan discharge
Full perimeter steel base rails
High and low pressure switches provide added reliability for the compressor
Cabinet air leakage of 2.0% or less at .5 in. W.C. when tested in accordance
with ASHRAE standard 193 (Low cabinet air leakage FIOP models only)
Models with factory installed options are identified with letters in the 14th and 15th positions in the model number
Hail guard (3/8” spacing) wire grilles standard on single phase models with optional factory installed
tin- plated copper evaporator coil (TP). All other models have 2” spacing wire grilles including
3- phase models
Single and 3- phase models with factory installed option for low cabinet air leakage and tin- plated
copper evaporator main tubes PHD4 (LC)
LIMITED WARRANTY*
1 Phase PHD4 “F” Models
3 year No Hassle Replacementt limited warranty for tin- plated ’TP’ models
10 year parts limited warranty (including compressor and coils) with timely registration
5 year parts limited warranty if not registered within 90 days of original installation
3 Phase PHD4 “F” Models
5 year compressor limited warranty
1 year parts limited warranty
* See warranty certificate for details and restrictions
UNIT PERFORMANCE DATA
Model
Number
COOLING HEATING
Unit Dimensions
Height x Width x Depth
in (mm)
Operating
Weight
lbs (kg)
Capacity
BTU/h
SEER EER
Capacity
BTU/h
HSPF
208/230- 1- 60
PHD424000K**0F 23,000 14.5 12.0 22,600 8.0 47
3
/
4
x48
3
/
16
x32
5
/
8
(1213 x 1224 x 829) 311 (141)
PHD430000K**0F 28,600 14.0 11.5 28,400 8.0 51
3
/
4
x48
3
/
16
x32
5
/
8
(1315 x 1224 x 829) 351 (159)
PHD436000†**0F 34,200 14.0 11.5 34,400 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 387 (176)
PHD442000†**0F 41,000 14.0 11.5 40,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 435 (197)
PHD448000†**0F 48,000 14.0 12.0 46,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 456 (207)
PHD460000†**0F 57,500 14.0 11.5 57,500 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 487 (221)
208/230- 3- 60
PHD436000†**0F 34,200 14.0 11.5 34,400 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 387 (176)
PHD442000†**0F 41,000 14.0 11.5 40,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 435 (197)
PHD448000†**0F 48,000 14.0 12.0 46,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 456 (207)
PHD460000†**0F 57,500 14.0 11.5 57,500 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 487 (221)
460-3-60
PHD436000†**0F 34,200 14.0 11.5 34,400 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 387 (176)
PHD442000†**0F 41,000 14.0 11.5 40,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 435 (197)
PHD448000†**0F 48,000 14.0 12.0 46,000 8.0 54
3
/
4
x48
3
/
16
x44
3
/
16
(1391 x 1224 x 1122) 456 (207)
PHD460000†**0F 57,500 14.0 11.5 57,500 8.0 48
3
/
4
x48
3
/
16
x44
3
/
16
(1238 x 1224 x 1122) 487 (221)
K = 208/230- 1- 60, H = 208/230- 3- 60, L =460-3-60
** 00 =NoOptions,TP = Tin- Plated Evaporator Main Tubes (Single Stage), LC = Low Cabinet Air Leakage plus Tin- Plated
Copper Evaporator Main Tubes
COMMERCI
AL
PHD4
Product Specifications

Summary of content (36 pages)