Owners Manual
PRODUCT SPECIFICATIONS Split System Heat Pump: NXH6
16 428 51 6203 00
Specifications subject to change wi thout notice.
ACCESSORY USAGE GUIDELINES
Accessory
REQUIRED FOR
LOW–AMBIENT
COOLING APPLICATIONS
(Below 55F / 12.8C)
REQUIRED FOR
LONG LINE
APPLICATIONS*
REQUIRED FOR
SEA COAST APPLICATIONS
(Within 2 miles / 3.22 km)
Accumulator Standard Standard Standard
Compressor Start Assist
Capacitor and Relay
Yes Yes No
Crankcase Heater Yes
Yes
No
Evaporator Freeze Thermostat Yes No No
Isolation Relay Yes No No
Liquid Line Solenoid Valve No
See Long–Line
Application Guideline
No
Low Ambient Switch Yes} No No
Support Feet Recommended No Recommended
* For tubing line sets between 80 an d 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differen tial, refer to Residential Piping and Longline Guideline.
} In units equipped with ECM OD motor, motor needs to be replaced per unit accessory guide to work properly . This motor kit comes with a new defrost board that
also needs to be installed. Unit will not meet AHRI rated efficiency once motor and defrost board are replaced to use this accessory.
ACCESSORIES
Part Number Description Used On Size
NASA00101IK ISLN Relay Kit ALL
NASA00601CH Crankcase Heater for Scroll Compressor (208/230 V) 18, 24, 30
NASA00501CH Crankcase Heater for Scroll Compressor (208/230 V) 42, 48
NASA001SC Start Component - PTC Device ALL
NASA00201FS Evaporator Freeze Thermostat ALL
NASA001LS Liquid Line Solenoid Valve Kit, HP, R- 22 or R- 410A ALL
NASA001TD T ime Delay Relay, Indoor Blower ALL
NASA001AC Anti- Cycle Timer (5 minute delay) ALL
NASA003SC Hard Start Kit (Capacitor & Relay) 36, 60
NASA007SC Hard Start Kit (Capacitor & Relay) 18, 24, 30, 42, 48
NASA00101PM* PSC Fan Motor Kit (motor , fan, and defrost board) 42, 60
NASA401LA Low Ambient Kit (Pressure Switch), R- 410A ALL
NASA00201SF Support Feet, 4” (102mm) tall, 5 included ALL
NASA00201SJ Sound Blanket Kit 18, 24, 30, 36
NASA00101SJ Sound Blanket Kit 42, 48, 60
NAEA40501TX TXV Kit, R- 410A - for use with copper or tin fan coils 18, 24, 30
NAEA40601TX TXV Kit, R- 410A - for use with copper or tin fan coils 36, 42
NAEA40701TX TXV Kit, R- 410A - for use with copper or tin fan coils 48, 60
NAEB40501TX TXV Kit, R- 410A - for use with aluminum fan coils 18, 24, 30
NAEB40601TX TXV Kit, R- 410A - for use with aluminum fan coils 36, 42
NAEB40701TX TXV Kit, R- 410A - for use with aluminum fan coils 48, 60
NASA00106SS Snow Stand Kit ALL
TST AT0201CW Observer Self Configuring Communicating Wall Control ALL
* Required to u se NASA401LA Low Ambient Kit with this unit. Unit will not meet AHRI rated eff iciency once this accessory is installed.
Copyright 2017 International Comfort Products
Lewisburg, Tennessee 37091 USA