Owners Manual
PRODUCT SPECIFICATIONS Split System Heat Pump: NXH6
428 51 62023 00 5
Specifications subject to change wi thout notice.
A- WEIGHTED SOUND LEVEL
Unit Size
Standard Rating
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dB without tone adjustment)
125 250 500 1000 2000 4000 8000
18 68 66.2 63.8 64.1 64.6 59.9 57.7 53.6
24 72 63.4 63.3 63.3 70.4 64.5 59.3 55.5
30 72 65.0 65.0 66.0 69.0 65.0 62.0 59.0
36 72 67.7 66.8 68.1 69.9 62.8 60.3 55.2
42 68 63.9 64.1 65.0 64.9 58.2 57.3 56.7
48 73 67.5 67.8 70.1 70.6 63.1 58.5 53.3
60 70 61.7 65.6 68.1 65.8 59.8 58.4 56.1
NOTE: Tested in accordance with AHRI Standard 270 - 08 (not listed in AHRI).
A- WEIGHTED SOUND LEVEL WITH ACCESSORY SOUND SHIELD
Unit Size
Standard Rating
(dBA)
TYPICAL OCTAVE BAND SPECTRUM (dB without tone adjustment)
125 250 500 1000 2000 4000 8000
18 67 66.2 63.9 63.8 62.3 58.4 56.4 50.3
24 71 65.0 63.7 63.4 68.5 64.7 58.7 52.8
30 70 67.1 66.3 66.6 66.9 62.9 58.1 53.0
36 71 68.2 66.4 67.5 68.4 59.6 58.2 52.4
42 68 63.0 64.2 66.3 63.5 57.1 55.4 55.8
48 71 68.4 67.7 69.7 67.6 59.4 56.4 50.0
60 69 63.7 65.4 67.3 64.9 58.3 56.2 51.9
NOTE: Tested in accordance with AHRI Standard 270 - 08 (not listed in AHRI).
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The s uction line
diameters shown in the chart below are acceptable for HP systems with R- 410A refrigerant:
R- 410A COOLING CAPACITY LOSS FOR VARIOUS LINE LENGTHS & TUBE DIAMETERS
Model
Size
Liquid
Line
in.(mm)
Acceptable
Vapor Line
Sizes
in. (mm)
Cooling Capacity Loss (%) at Total Equivalent Line Length, feet (m)
Refer to Long Line Application Guideline to calculate equivalent length
Standard Application Long Line Application (Requires Accessories)
25’
(7.6)
50’
(15.2)
80’
(24.4)
81’
(24. 7)
100’
(30.5)
125’
(38.1)
150’
(45.7)
175’
(53.3)
200’
(61)
225’
(68.6)
250’
(76.2)
18
3/8 (10)
1/2 (13) 1 2 3 3 4 6 7 8 9 10 12
5/8 (16) 0 0 1 1 1 1 2 2 3 3 3
24
5/8 (16) 0 1 1 1 2 3 3 4 4 5 6
3/4 (19) 0 0 0 0 0 1 1 1 1 1 2
30
5/8 (16) 1 2 3 3 3 4 5 6 7 8 9
3/4 (19) 0 0 1 1 1 1 2 2 2 3 3
7/8 (22) 0 0 0 0 0 1 1 1 1 1 1
36
5/8 (16) 1 2 4 4 5 6 7 9 10 11 13
3/4 (19) 0 0 1 1 1 2 2 3 3 4 4
7/8 (22) 0 0 0 0 0 1 1 1 1 2 2
42
3/4 (19) 0 1 2 2 2 3 4 4 5 6 6
7/8 (22) 0 0 1 1 1 1 2 2 2 3 3
48
3/4 (19) 0 1 2 2 3 4 5 5 6 7 8
7/8 (22) 0 0 1 1 1 2 2 2 3 3 4
60
3/4 (19) 1 2 4 4 5 6 7 9 10 11 12
7/8 (22) 0 1 2 2 2 3 4 4 5 5 6
1- 1/8 (29) 0 0 0 0 1 1 1 1 1 1 2
* Applications are considered “Long Line” if the total equivalent tubing length exceeds 80 feet (24.4m) or there is more than 20 foot (6.1m) vertical separation
between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation.
Applications in this area may have height restrictions that limit allowable total equivalent length when outdoor unit is below indoor unit.