Service Manual

SERVICE AND MAINTENANCE FAN COILS
496 08 8001 02 7
Specifications subject to change without notice.
Fuse Data: 5amp automotivetype ATC/ATO (tan) at 32Vac,
200 percent current opening time of five seconds maximum.
Electrical Connections
Twentyone 0.110in pin terminals are used to provide
programming selections for operating modes of ECM 5.0. The
6 selection modes are listed below. For additional information,
refer to Easy Select Configuration Taps section.
AUX Heat Range—(Violet Wire)
AC/HP Size—(Blue Wire) Type—(Orange Wire)
AC/HP CFM Adjust—(Black Wire)
AC/HP Time Delay—(Grey Wire)
Continuous Fan—(Yellow Wire)
SEQUENCE OF OPERATION
A. Continuous Fan Mode
The thermostat closes circuit R to G. The unit delivers the
airflow selected for fan only operation.
B. Cooling Mode—Single Speed or TwoSpeed High
Thermostat closes circuits R to G, R to Y/Y2 and R to O (heat
pump only). A circuit R to Y1 is required for twospeed high
operation. Airflow delivered the airflow selected by AC/HP
SIZE selection and CFM ADJUST selection.
C. Cooling Mode—TwoSpeed Low
Thermostat closes R to G and R to Y1 and R to O (heat pump
only). Unit delivers twospeed low airflow for AC/HP SIZE and
CFM ADJUST selected.
D. Cooling + Dehumidify Mode
J1 jumper must be pulled from Easy Select Board. Control
closes R to G, R to Y/Y2, and R to O (heat pump only) and
open R to DH. Dehumidification is active when 24Vac is
removed from DH terminal. Unit delivers 20 percent less
airflow.
E. Super Dehumidify Mode
This mode is only activated when the control closes R to Y/Y2,
R to O (heat pump only) and opens R to DH and R to G. This
signals the fan coil to run at minimum airflow for maximum
humidity removal. The control will cycle the equipment 10
minutes on and 10 minutes off until satisfied.
Table 1 – Motor and Modules
Model Size
Motor Type
Current Blower Motor
P/N
Required Control Module
Replacement Kit Number
FVM4X2400 (Series B) ECM 5.0 1185246 1185326
FVM4X3600 (Series B) ECM 5.0 1185247 1185327
FVM4X4800 (Series B) ECM 5.0 1185248 1185328
FVM4X6000 (Series B) ECM 5.0 1185249 1185329
Figure 5 Easy Select Board 1185358
YYWWX
AUX/HEAT KW/CFM
AC/HP SIZE
AC/HP CFM ADJUST
ON/OFF DELAY
CONTINUOUS FAN
HEATER/MOTOR
AUX1 HUM1
AUX2
24VAC
HUM2
LO MED HI YEL
SYSTEM TYPE
SEC1
®
®
EASY SELECT
SEC2
J1
5 AMP.
MAX.
F1
D4
D5D2
D3
D1
R1
R2
HK61EA006
5
STI
J2
YEL
PL1
GRY
WHT
BLK
ORN
BLU
VIO
0-30
1075
0-20
875
0-10
725
0-5
625
036 030 024 018
AC HP-COMFORT HP-EFF
NOM LO HI
0
90
30
90
0
0
ENH
D
H
R
W
1
W
2
Y
1
Y/Y
2
G
O
C
1