Product Specifications

PRODUCT SPECIFICATIONS Gas Furnace: N95ESN
3 440 51 4501 00
Specifications subject to change without notice.
PHYSICAL DATA
Heating Capacity and Efficiency 0261410 0401410 0401712 0601412 0601714 0801716 0802120 1002120 1202422 1402422
Input
High Heat
(BTUH)
26,000 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000 140,000
Output
High Heat
(BTUH)
25,000 39,000 39,000 58,000 58,000 78,000 78,000 97,000 117,000 135,000
Certified Temperature
Rise Range ºF (ºC)
High Heat
25  55
(14  31)
40  70
(22  39)
40  70
(22  39)
45  75
(25  42)
40  70
(22  39)
40  70
(22  39)
40  70
(22  39)
40  70
(22  39)
40  70
(22  39)
45  75
(25  42)
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
Heating 0.10 0.10 0.10 0.12 0.12 0.12 0.12 0.15 0.20 0.20
Cooling 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
Airflow Delivery @ Rated
ESP (CFM)
High Heat 605 695 650 930 1010 1325 1330 1730 2020 2130
Cooling 895 950 1010 1120 1330 1665 1855 2125 2105 2310
Cooling Capacity (tons)@
400, 350 CFM/ton
CFM/ton 2 2 2.50 2.50 3.50 4 5 5 5 5
CFM/ton 2.50 2.50 3 3 4 4.50 5.50 6 6 6
DirectDrive Motor Type Electronically Commutated Motor (ECM)
DirectDrive Motor HP 1/3 1/2 1/2 1/2 3/4 3/4 1 1 1 1
Motor Full Load Amps 4.4 6.3 6.8 6.3 8.8 9.2 11.5 11.7 11.5 11.7
RPM Range
400 
1200
600 
2000
400 
1200
600 
2000
400 
1200
400 
1200
400 
1200
400 
1200
400 
1200
400 
1200
Speed Selections 5 5 5 5 5 5 5 5 5 5
Blower Wheel Dia x
Width
in. 11 x 7 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 11 x 11
Air Filtration System Field Supplied Filter
Filter Used for Certified Watt Data NAHA00*06FB
Electrical Data
Input Voltage
VoltsHertz
Phase
115601
Operating Voltage Range MinMax 104127
Maximum Input Amps Amps 5.1 7.0 7.5 7.1 9.6 10 12.3 12.6 12.4 12.6
Unit Ampacity Amps 7.3 9.7 10.3 9.8 12.9 13.4 16.3 16.7 16.4 16.7
Minimum Wire Size AWG 14 14 14 14 14 14 12 12 12 12
Maximum Wire Length@
Minimum Wire Size
Feet 50 38 36 38 28 27 35 34 35 34
(M) (15.5) (11.7) (10.9) (11.5) (8.7) (8.4) (10.7) (10.5) (10.7) (10.5)
Maximum Fuse/Ckt Bkr
(TimeDelay Type Rec
ommended)
Amps 15 15 15 15 15 15 20 20 20 20
Transfomer Capacity (24vac output) 40 VA
External Control Power
Available
Heating 27.9 VA
Cooling 34.6 VA
Controls
Gas Connection Size 1/2"  NPT
Burners (Monoport) 2 2 2 3 3 4 4 5 6 7
Gas Valve (Redundant) Manufacturer White Rodgers
Minimum Inlet Gas pressure (in. wc) 4.50
Maximum Inlet Gas pressure (in. wc) 13.60
Manufactured (Mobile) Home Kit See Accessory Listing
Ignition Device Silicon Nitride
Heating Blower Control
(Heating OffDelay)
Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control
(Time Delay Relay)
90 seconds
Communication System none
Thermostat Connections Com 24V, R, W, G, Y
Accessory Connections EAC (115vac); HUM (24vac); 1stg AC (via Y)