Installation Manual

16 428 01 5700 02
Specifications subject to change without notice.
TECHNICAL LABELS
824 Size Outdoor With FCM4X24***L Stage 5 Indoor Cooling
Outdoor Ambient Temperature - Degrees F, Dry Bulb
65 75 85 95 105 115#
Entering Indoor Temperature - Degrees F, Wet Bulb
STAGE- 5 Mode 72 67 63†† 57 72 67 63†† 57 72 67 63†† 57 72 67 63†† 57 72 67 63†† 57 72 67 63†† 57
SCFM 708 663 634 608 642
MBh[
29.23 26.51 24.55 23.16 27.93 25.31 23.44 22.06 26.67 24.17 22.39 21.12 25.37 23.00 21.29 20.17 24.55 22.26 20.62 19.90
Comfort
S/T]
0.52 0.70 0.73 1.00 0.52 0.70 0.73 1.00 0.52 0.70 0.73 1.00 0.52 0.71 0.73 1.00 0.54 0.73 0.76 1.00
+ AMPS* 5.78 5.82 5.85 5.85 6.95 6.94 6.94 6.93 8.25 8.20 8.15 8.11 9.67 9.56 9.47 9.40 11.31 11.15 11.02 10.97
De- Humidify HI PR 261 257 254 252 300 295 292 289 343 337 333 331 390 384 380 377 438 431 426 424
LO PR 156 142 132 125 156 142 132 125 157 143 133 126 158 144 134 128 162 148 137 133
Efficiency
SCFM 825 825 825 825 825 825
MBh[
29.93 27.14 25.14 24.28 28.85 26.16 24.25 23.62 27.69 25.12 23.28 22.90 26.44 24.00 22.25 22.11 25.31 22.96 21.29 21.38 23.92 21.71 20.14 20.46
S/T]
0.54 0.73 0.76 1.00 0.54 0.75 0.77 1.00 0.55 0.77 0.79 1.00 0.56 0.79 0.81 1.00 0.57 0.81 0.83 1.00 0.59 0.83 0.86 1.00
AMPS* 5.93 5.98 6.01 6.02 7.18 7.18 7.17 7.17 8.55 8.50 8.45 8.44 10.05 9.94 9.85 9.84 11.66 11.50 11.37 11.38 13.40 13.18 13.00 13.04
HI PR 263 258 255 254 302 297 293 292 346 340 336 335 394 387 383 383 441 434 429 429 498 490 484 486
LO PR 160 146 136 132 162 148 138 135 164 150 139 138 166 152 141 141 168 154 143 144 170 156 145 148
Maximum
SCFM 848 840 833 825 825 825
MBh[
29.56 26.97 25.11 24.40 28.53 26.03 24.24 23.71 27.43 25.04 23.23 22.97 26.27 23.99 22.33 22.18 25.23 23.00 21.40 21.46 23.91 21.82 20.31 20.58
S/T]
0.54 0.74 0.77 1.00 0.55 0.76 0.78 1.00 0.56 0.77 0.80 1.00 0.56 0.79 0.81 1.00 0.57 0.80 0.83 1.00 0.59 0.83 0.85 1.00
AMPS* 5.80 5.90 5.97 5.99 7.06 7.12 7.17 7.17 8.45 8.47 8.46 8.48 9.97 9.94 9.91 9.91 11.63 11.54 11.48 11.49 13.39 13.26 13.15 13.18
HI PR 256 253 252 252 296 293 292 291 341 338 335 336 391 387 385 385 440 436 433 434 498 494 491 492
LO PR 161 147 137 133 163 149 138 136 164 150 140 138 166 152 141 141 168 153 143 144 170 156 145 147
824 Size Outdoor With FCM4X24***L Indoor Heating
Outdoor Ambient Temperature - Degrees F, Dry Bulb
7 17 27 37 47 57
Entering Indoor Temperature - Degrees F, Dry Bulb
STAGE- 5 Mode 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75 65 70 75
Comfort
SCFM 402 523 621 720 819 540
MBh[
11.97 11.86 11.66 15.44 15.28 15.11 18.09 17.90 17.71 21.48 21.22 20.95 24.94 24.60 24.26 16.37 15.99 15.67
T/R 23.47 28.66 28.12 31.32 30.92 30.51 30.47 30.09 29.69 30.80 30.35 29.90 31.00 30.52 30.03 30.24 29.47 28.83
AMPS* 5.83 6.46 6.72 7.84 8.22 8.61 7.88 8.28 8.70 8.09 8.51 8.95 8.23 8.68 9.13 4.63 4.94 5.28
HI PR 282 328 347 319 340 362 315 336 358 317 337 359 318 338 359 303 320 341
LO PR 47 47 102 57 58 58 69 70 70 85 86 86 102 102 103 132 132 133
Efficiency
SCFM 450 825 825 825 825 650
MBh[
12.00 11.90 11.70 15.76 15.60 15.44 18.37 18.18 17.99 21.73 21.46 21.18 24.94 24.60 24.26 16.71 16.37 16.03
T/R 23.47 25.69 25.21 20.26 20.01 19.75 23.29 23.00 22.71 27.18 26.78 26.37 30.78 30.30 29.81 25.65 25.07 24.50
AMPS* 5.83 6.29 6.54 7.33 7.71 8.09 7.55 7.96 8.37 7.92 8.35 8.79 8.22 8.66 9.11 4.39 4.71 5.04
HI PR 282 315 333 274 294 314 287 306 327 302 322 343 316 336 357 285 303 322
LO PR 47 47 102 57 57 57 69 69 70 85 85 86 102 102 102 131 132 133
Maximum
SCFM 500 830 837 843 850 650
MBh[
12.05 11.91 11.77 15.77 15.61 15.45 18.38 18.19 18.01 21.75 21.49 21.25 25.01 24.68 24.39 16.69 16.39 16.09
T/R 23.47 23.15 22.82 20.15 19.90 19.65 22.98 22.68 22.40 26.62 26.25 25.89 29.96 29.50 29.09 25.62 25.11 24.59
AMPS* 5.83 6.15 6.45 7.33 7.71 8.10 7.54 7.95 8.37 7.90 8.34 8.78 8.18 8.63 9.10 4.38 4.72 5.07
HI PR 282 303 324 274 293 314 285 305 326 300 320 341 313 333 355 284 303 323
LO PR 47 47 102 57 57 57 69 69 69 85 85 86 102 102 102 131 132 132
See Legend on page 22.