Specifications
PRODUCT SPECIFICATIONS Fan Coils: FCM4X
2 496 51 4202 02
Specifications are subject to change without notice.
FAN COIL MODEL NUMBER IDENTIFICATION GUIDE
DIGIT POSITION
1 2 3 4 5 6,7,8,9 10 11
F C M 4 X 1800 A L
F=FanCoil UNIT
V = Variable speed
C = Communicating ECM MOTOR TYPE
M = Multiposition
U=Upflow INSTALLATION TYPE
4 = Environmentally Sound R- 410A REFRIGERANT
X=TXV METERING DEVICE
2400 = 24,000 BTUH = 2 tons
3600 = 36,000 BTUH = 3 tons
4800 = 48,000 BTUH = 4 tons
6000 = 60,000 BTUH = 5 tons NOMINAL CAPACITY
A = Copper Tube, Aluminum Fin Evaporator Coil
AL = Aluminum T ube, Aluminum Fin Evaporator Coil
AT = Tin Coated Copper Tube, Aluminum Fin Evaporator Coil SALESCODE/FEATURES
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
EB AC 01 NCB A
EB = Evaporator Blower
AC = Accessory
01 = Product Identifier Number
NCB = Non- Combustible Base Kit
DFK = Down Flow Kit
PLG = Power Plug (no heat kit)
SPK = Single Point Wiring Kit
FKS = Filter Kit Small
FKM = Filter Kit Medium
FKL = Filter Kit Large
FKX = Filter Kit Extra Large
CTK = Condensate Trap Kit (PVC pipe)
Sales Code
ELECTRIC HEATER MODEL NUMBER IDENTIFICATION GUIDE
EHC 09 A K N 1
EHC = Communicating Electric Heater Kit
EHK = Standard Electric Heater Kit
05 = 5 kW
07 = 8 kW
09 = 9 kW
10 = 10 kW
15 = 15 kW
18 = 18 kW
20 = 20 kW
25 = 24 kW
30 = 30 kW NOMINAL HEAT VALUE
Sales Code
K = 208 / 230 single- phase
H = 208 / 230, 3- phase
KC = 208 / 230, supplied as single phase, field convertible to 3- phase
HC = 208 / 230 supplied as 3- phase, field convertible to single phase VOLTAGE (60 Hz)
N = No protection
F = Fused
B = Breaker Electrical Protection
Engineering Code