Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: HVH8
7 428 51 5900 03
Specifications subject to change without notice.
RPMCAPACITYSOUND (dBA)*
STAGE # COMP RPM CAPACITY % SOUND (dBA)
HVH824
COOLING
1 1500 35% 56
2 2566 56% 60
3 3150 69% 65
4 3950 87% 66
5 4700 100% 67
HEATING
1 1500 29% 56
2 2800 53% 59
3 3150 59% 62
4 4700 88% 65
5 5400 100% 68
HVH825
COOLING
1 1200 38% 56
2 1900 58% 60
3 2400 73% 62
4 2600 79% 66
5 3300 100% 69
HEATING
1 1200 25% 56
2 2400 50% 60
3 3300 69% 62
4 4200 88% 68
5 4800 100% 71
HVH836
COOLING
1 1200 25% 56
2 2400 50% 61
3 3300 69% 65
4 4200 88% 69
5 4800 100% 72
HEATING
1 1200 22% 56
2 2600 48% 60
3 3400 63% 63
4 4800 89% 69
5 5400 100% 71
HVH837
COOLING
1 1200 25% 60
2 1800 60% 61
3 2200 73% 67
4 2600 87% 67
5 3000 100% 69
HEATING
1 1200 25% 60
2 2400 50% 67
3 2700 56% 68
4 3000 63% 69
5 4800 100% 72
HVH848
COOLING
1 1500 35% 64
2 2460 57% 67
3 2800 65% 68
4 3650 84% 70
5 4320 100% 72
HEATING
1 1500 28% 64
2 2800 52% 67
3 3300 61% 68
4 4320 80% 71
5 5400 100% 74
HVH860
COOLING
1 1200 32% 57
2 2180 55% 61
3 2850 70% 65
4 3700 90% 68
5 4140 100% 72
HEATING
1 1200 25% 57
2 2600 50% 51
3 3200 61% 65
4 4140 88% 69
5 5400 100% 71
*Estimated sound for stages 2, 3, and 4
*For 2-stage operation: Cooling Low = Stage 2, Heating low = Stage 3; both cooling and heating High = Stage 5