Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: HVH8
48 428 51 5900 03
Specifications subject to change without notice.
SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than
0.01in. wc.
2. This product is not qualified for low ambient cooling operation.
Minimum cooling outdoor operating temperatures:
Communicating systems: 40_F (4.44_C)
Noncommunicating systems: 55_F (12.8_C)
3. The maximum outdoor operating ambient in cooling mode is 115_F (46.11_C).
4. Minimum outdoor operating air temperature for heating mode is 10_F (–12.2_C).
5. Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C).
6. For reliable operation, unit should be level in all horizontal planes.
7. This unit is qualified for up to 100 ft (30.5 m) equivalent length of line set without additional accessories.
8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant
tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer
than 36 in. (914.4 mm).
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of con-
nector provided.
10. Do not apply capillary tube indoor coils to these units.
11. R410A refrigerant TXV required on indoor coil.
Accessory Description and Usage
Support Feet
Raises unit above base pad. 2 and 3 ton kit contains 5 feet for
stable installation with small base. 4 and 5 ton kit contains 4
feet.
Usage Guideline:
Recommended in cold climates where snow can
accumulate around unit. Allows improved base pan drainage.
Recommended for rooftop applications.
Thermostatic Expansion Valve (TXV)
A modulating flowcontrol valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of
the refrigerant gas leaving the evaporator.
Usage Guideline:
Required if indoor unit does not already contain
R410A refrigerant TXV
Vapor Line Muffler
An external muffler installed in the vapor line to minimize
vibration transmitted through refrigerant lines
Usage Guideline:
Recommended if vapor line is not installed per
recommendations in the installation instructions and vibration
may be transmitted into the structure.
WALL CONTROL
TSTAT0201CW
Observer
®
Self Configuring Communicating Wall Control
ALL
ACCESSORY USAGE GUIDELINES
KIT NUMBER
Unit Size (Voltage/Series)
24 25 36 37 48 60
NASA00201SF Support Feet, 4” (102mm) tall X X X X X X
NAEA40501TX
TXV Kit, R410A
2010 and later Piston Coils
X X
NAEA40601TX X X
NAEA40701TX X X
NAEB40501TX
TXV Kit, R410A
2010 and later Piston Coils
X
NAEB40601TX X X
NAEB40701TX X
1187979 Vapor Line Muffler X X X X X X
X = Accessory
Copyright 2016 International Comfort Products
Lewisburg, Tennessee 37091 USA