Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: HVH8
44 428 51 5900 03
Specifications subject to change without notice.
HVH860
HEAT PUMP HEATING PERFORMANCE EFFICIENCY MODE
INDOOR AIR
HVH860 / FCM4X60***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
7 (-13.9) 17 (-8.3) 27 (-2.8)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
840
29.44 27.05 3.99
1600
48.43 44.16 6.49
1600
55.69 49.46 6.61
70 (21.1) 29.47 27.09 4.22 49.06 44.73 7.02 56.12 49.84 7.10
75 (23.3) 29.57 27.17 4.47 49.80 45.40 7.61 56.61 50.28 7.63
STAGE 3
65 (18.3)
700
20.47 18.81 2.46
900
24.06 21.94 2.39
1275
28.38 25.21 2.32
70 (21.1) 20.30 18.66 2.58 23.86 21.75 2.51 28.08 24.94 2.44
75 (23.3) 20.25 18.60 2.73 23.67 21.58 2.64 27.78 24.68 2.56
STAGE 1
65 (18.3)
700
20.47 18.81 2.46
900
24.06 21.93 2.39
1275
21.17 18.80 1.57
70 (21.1) 20.31 18.66 2.58 23.85 21.75 2.51 20.88 18.55 1.56
75 (23.3) 20.27 18.62 2.73 23.66 21.57 2.64 20.60 18.30 1.65
INDOOR AIR
HVH860 / FCM4X60***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
37 (2.8) 47 (8.3) 57 (13.9)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
1600
64.63 58.81 6.84
1600
73.25 73.25 7.06
1400
43.82 43.82 2.61
70 (21.1) 64.85 59.01 7.31 73.27 73.27 7.50 43.06 43.06 2.72
75 (23.3) 65.13 59.27 7.81 73.33 73.33 7.98 42.35 42.35 2.83
STAGE 3
65 (18.3)
1275
33.13 30.14 2.42
1275
38.00 38.00 2.52
1400
43.82 43.82 2.61
70 (21.1) 32.71 29.76 2.53 37.45 37.45 2.63 43.06 43.06 2.72
75 (23.3) 32.29 29.38 2.65 36.91 36.91 2.75 42.35 42.35 2.83
STAGE 1
65 (18.3)
1275
24.69 22.46 1.57
900
16.76 16.76 0.84
900
19.39 19.39 0.96
70 (21.1) 24.31 22.12 1.66 16.40 16.40 0.93 18.97 18.97 1.06
75 (23.3) 23.94 21.78 1.76 16.04 16.04 1.02 18.56 18.56 1.16
Operation in this area is restricted to maintain reliable system operation and customer comfort. The system will default to the next available stage
Stage 5 - Compressor speed limited to stage four at 7 and stage three at 57 outdoor; Stage 1 - Compressor speed limited to stage three at 7 and 17 and to stage twp at 27 and 37 outdoor.
See additional notes on page 45