Specifications

PRODUCT SPECIFICATIONS Split System Heat Pump: HVH8
26 428 51 5900 03
Specifications subject to change without notice.
HVH836
HEAT PUMP HEATING PERFORMANCE EFFICIENCY MODE
INDOOR AIR
HVH836 / FCM4X48***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
7 (-13.9) 17 (-8.3) 27 (-2.8)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
450
16.00 14.70 2.35
1200
23.19 21.15 2.51
1200
26.38 23.43 2.48
70 (21.1) 15.90 14.61 2.44 23.00 20.97 2.61 26.13 23.21 2.60
75 (23.3) 15.75 14.48 2.53 22.80 20.79 2.72 25.87 22.98 2.71
STAGE 3
65 (18.3)
360
10.11 9.29 1.52
500
12.21 11.13 1.49
900
14.64 13.01 1.31
70 (21.1) 9.99 9.18 1.58 12.06 10.99 1.56 14.47 12.85 1.38
75 (23.3) 9.87 9.07 1.64 11.91 10.86 1.63 14.29 12.69 1.45
STAGE 1
65 (18.3)
360
10.10 9.28 1.51
500
12.21 11.14 1.49
900
10.13 9.00 0.92
70 (21.1) 9.98 9.17 1.57 12.06 11.00 1.56 9.98 8.86 0.96
75 (23.3) 9.85 9.06 1.64 11.92 10.86 1.63 9.83 8.73 1.01
INDOOR AIR
HVH836 / FCM4X48***L Heating Efficiency Mode
Outdoor Coil Entering Air Temperature °F (°C)
37 (2.8) 47 (8.3) 57 (13.9)
EDB
°F (°C)
ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW† ID SCFM
Capacity MBtuh
Total Sys. KW†
Total Integ‡ Total Integ‡ Total Integ‡
STAGE 5
65 (18.3)
1200
30.62 27.87 2.60
1200
34.60 34.60 2.69
900
22.12 22.12 1.39
70 (21.1) 30.29 27.56 2.72 34.20 34.20 2.82 21.86 21.86 1.48
75 (23.3) 29.94 27.24 2.84 33.79 33.79 2.94 21.51 21.51 1.57
STAGE 3
65 (18.3)
900
17.02 15.49 1.35
900
19.45 19.45 1.35
900
22.19 22.19 1.38
70 (21.1) 16.79 15.28 1.42 19.17 19.17 1.44 21.81 21.81 1.47
75 (23.3) 16.57 15.08 1.50 18.89 18.89 1.52 21.45 21.45 1.56
STAGE 1
65 (18.3)
900
11.92 10.84 0.92
700
7.88 7.88 0.44
700
9.16 9.16 0.42
70 (21.1) 11.73 10.68 0.98 7.70 7.70 0.49 8.95 8.95 0.47
75 (23.3) 11.55 10.51 1.04 7.52 7.52 0.53 8.74 8.74 0.52
Operation in this area is restricted to maintain reliable system operation and customer comfort. The system will default to the next available stage
Stage 5 - Compressor speed limited to stage four at 7 and stage three at 57 outdoor; Stage 1 - Compressor speed limited to stage three at 7 and 17 and to stage two at 27 and 37 outdoor.
See additional notes on page 45