Specifications
PRODUCT SPECIFICATIONS Split System Air Conditioner: HVA9
421 51 5800 02 9
Specifications subject to change without notice.
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory. www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Airquest database at:
http://www.icpeqp.com/AHRIratings/ratings.aspx?Brand=Airquest
Or scan this QR code:
Model Number Coil Model Number
Furnace Model
Number
Stages
Cooling Capacity
High
SEER EER ID CFM
HVA924GKA101
FCM4X24***L + WALLCON 5 24,000 18.0 11.0 825
HVA924GKA101
FVM4X24***L 2 23,800 16.0 11.0 700
HVA925GKA101
FCM4X48***L + WALLCON 5 24,000 19.0 12.5 825
HVA925GKA101
FVM4X36***L 2 22,600 19.0 12.2 700
HVA936GKA101
FCM4X48***L + WALLCON 5 35,000 18.0 10.5 1050
HVA936GKA101
FVM4X48***L 2 35,000 16.0 10.5 1050
HVA937GKA101
FCM4X60***L + WALLCON 5 33,600 19.0 13.0 1050
HVA948GKA101
FCM4X60***L + WALLCON 5 46,500 19.0 11.0 1400
HVA948GKA101
FVM4X60***L 2 46,000 15.5 11.0 1400
HVA949GKA101
FCM4X60***L + WALLCON 5 45,500 19 12.5 1400
HVA960GKA101
FCM4X60***L + WALLCON 5 57,000 17.0 10.0 1600
HVA960GKA101
FVM4X60***L 2 57,500 15.0 10.0 1750
Ratings with “+ WALLCON” are communicating systems with Observer® Wall Control and 5-stages of operation.
Ratings without “+ WALLCON” are non-communicating systems with 2-stage operation.
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
WALLCON — Wall Control
NOTE: Ratings contained in this document are subject to change at any time.