Specifications

PRODUCT SPECIFICATIONS Split System Air Conditioner: HVA9
28 421 51 5800 02
Specifications subject to change without notice.
DETAILED COOLING CAPACITIES
#
EFFICIENCY MODE & COMFORT + DEHUMIDIFY MODE CONTINUED
HVA960
COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL
FCM4X60***L 1.00 1.00
EA*4X60L21A* 0.98 1.03 *9MA*0602120A**
EA*4X60L21A* 0.99 1.04 *9MA*0802120A**
EA*4X60L21A* 0.99 1.04 *9MA*1002122A**
EA*4X60L21A* 0.99 0.99 *8MV*1102120**
EA*4X60L24A* 0.98 1.03 *9MA*0602120A**
EA*4X60L24A* 0.99 1.04 *9MA*0802120A**
EA*4X60L24A* 0.99 0.99 *9MA*1002122A**
EA*4X60L24A* 0.99 1.04 *9MA*1202422A**
EA*4X60L24A* 0.99 0.99 *8MV*1102120**
EA*4X60L24A* 0.99 0.99 *8MV*1352422**
ENH4X60L24** 0.98 1.09 *9MA*0602120A**
ENH4X60L24** 0.99 1.04 *9MA*0802120A**
ENH4X60L24** 0.99 1.04 *9MA*1002122A**
ENH4X60L24** 0.99 1.04 *9MA*1202422A**
ENH4X60L24** 0.99 1.04 *8MV*1102120**
ENH4X60L24** 0.99 0.99 *8MV*1352422**
ENH4X61L24** 0.98 1.09 *9MA*0602120A**
ENH4X61L24** 0.99 1.04 *9MA*0802120A**
ENH4X61L24** 0.99 1.04 *9MA*1002122A**
ENH4X61L24** 0.99 1.04 *9MA*1202422A**
ENH4X61L24** 0.99 1.04 *8MV*1102120**
ENH4X61L24** 1.00 1.00 *8MV*1352422**
EN(A,D,W)4X60L24** 0.97 1.02 *9MA*0602120A**
EN(A,D,W)4X60L24** 0.98 1.03 *9MA*0802120A**
EN(A,D,W)4X60L24** 0.98 0.98 *9MA*1002122A**
EN(A,D,W)4X60L24** 0.98 1.03 *9MA*1202422A**
EN(A,D,W)4X60L24** 0.98 0.98 *8MV*1102120**
EN(A,D,W)4X60L24** 0.98 0.98 *8MV*1352422**
EN(A,D)4X61L24** 0.99 1.04 *9MA*0602120A**
EN(A,D)4X61L24** 0.99 1.04 *9MA*0802120A**
EN(A,D)4X61L24** 1.00 1.00 *9MA*1002122A**
EN(A,D)4X61L24** 0.99 0.99 *9MA*1202422A**
EN(A,D)4X61L24** 1.00 1.00 *8MV*1102120**
EN(A,D)4X61L24** 1.00 1.00 *8MV*1352422**
EHD4X60AAL 0.99 1.04 *9MA*0602120A**
EHD4X60AAL 0.99 1.04 *9MA*0802120A**
EHD4X60AAL 1.00 1.00 *9MA*1002122A**
EHD4X60AAL 1.00 1.00 *9MA*1202422A**
EHD4X60AAL 1.00 1.00 *8MV*1102120**
EHD4X60AAL 1.00 1.00 *8MV*1352422**
2STAGE (HiStage 5, LoStage 2)
COOLING INDOOR
MODEL
HIGH
SPEED
CAP.
POWER
LOW
SPEED
CAP.
POWER FURNACE MODEL
FVM4X60***L 1.00 1.00 1.00 1.00
EA*4X60L21A* 0.99 1.04 1.01 1.11 *9MX*0802120A**
EA*4X60L24A* 1.00 1.05 1.01 1.11 *9MX*1202422A**
EA*4X60L24A* 1.00 1.05 1.01 1.09 OLV154F20A
ENH4X60L24** 1.00 1.05 1.01 1.11 *9MX*1202422A**
ENH4X61L24** 1.00 1.05 1.01 1.10 *9MX*1202422A**
EN(A,D,W)4X60L24** 0.99 1.04 1.01 1.11 *9MX*1202422A**
EN(A,D,W)4X60L24** 0.99 1.04 1.01 1.09 OLV154F20A
EN(A,D)4X61L24** 1.00 1.05 1.01 1.09 *9MX*1202422A**
EN(A,D)4X61L24** 1.01 1.06 1.01 1.07 OLV154F20A
EN(A,D)4X61L24** 1.01 1.06 1.01 1.11 OMV154L20A
EHD4X60AAL 1.00 1.05 1.01 1.10 *9MX*0802120A**
EHD4X60AAL 1.00 1.05 1.00 1.09 *9MX*1202422A**
EHD4X60AAL 1.01 1.06 1.00 1.11 OMV154L20A
NOTES:
* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat
has been subtracted.
} Sensible capacities are shown for both 80_F (27_C) and 75_F
(23.4_C) entering air at the indoor coil.
For sensible capacities at other than these, deduct 835 Btuh (245 kW)
per 1000 CFM (480 L/S) of indoor coil air for each degree below refer
ence temperature, or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of
indoor coil air for each degree above reference temperature.
# Detailed cooling capacities are based on indoor and outdoor unit at
the same elevation per AHRI standard 210/240-2008. If additional tub
ing length and/or indoor unit is located above outdoor unit, a slight varia
tion in capacity may occur.
** System kw is total of indoor and outdoor unit kilowatts.
NOTE: When the required data falls between the published data, inter
polation may be performed. Extrapolation is not an acceptable practice.
EWB — Entering Wet Bulb