Specifications

PRODUCT SPECIFICATIONS Split System Air Conditioner: HVA9
22 421 51 5800 02
Specifications subject to change without notice.
HVA948
DETAILED COOLING CAPACITIES
#
COMFORT + DEHUMIDIFY MODE CONTINUED
EDB
°F (°C)
EVAP. AIR
HVA948 / FCM4X60***L Comfort + Dehumidify Mode
Condenser Entering Air Temperature °F (°C)
105 (40.5) 95 (35) 85 (29.4) 75 (23.9) 65 (18.3)
EWB
°F (°C)
ID
SCFM
Capacity MBtuh
Total Sys.
KW
ID SCFM
Capacity MBtuh
Total Sys.
KW
ID SCFM
Capacity MBtuh
Total Sys.
KW
ID SCFM
Capacity MBtuh
Total Sys.
KW
ID SCFM
Capacity MBtuh
Total Sys.
KWTotal Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
STAGE 5
75
(23.9)
72
(22.2)
1110
46.42 18.85 4.71
1184
49.80 20.23 4.17
1247
53.09 21.57 3.65
1330
56.46 22.96 3.19
1226
58.44 23.68 2.67
67
(19.4)
42.40 24.08 4.63 45.50 25.89 4.11 48.51 27.62 3.61 51.61 29.50 3.17 53.38 29.85 2.67
63
(17.2)
39.38 28.15 4.57 42.27 30.30 4.06 45.08 32.33 3.58 47.99 34.60 3.15 49.62 34.64 2.66
57
(13.9)
35.31 34.09 4.47 37.94 36.72 3.98 40.49 39.19 3.53 43.14 41.99 3.12 44.52 41.65 2.64
80
(26.7)
72
(22.2)
1110
46.26 23.95 4.71
1184
49.62 25.75 4.16
1247
52.90 27.46 3.65
1330
56.25 29.32 3.19
1226
58.25 29.68 2.67
67
(19.4)
42.29 29.13 4.63 45.38 31.35 4.10 48.38 33.45 3.61 51.47 35.79 3.17 53.26 35.77 2.67
63
(17.2)
39.31 33.18 4.57 42.20 35.74 4.06 45.01 38.14 3.58 47.91 40.87 3.15 49.54 40.54 2.66
57
(13.9)
36.80 36.80 4.51 39.58 39.58 4.01 42.24 42.24 3.55 45.10 45.10 3.13 45.76 45.76 2.65
STAGE 3
75
(23.9)
72
(22.2)
744
29.62 12.03 2.44
801
31.87 12.96 2.16
842
34.08 13.86 1.91
887
36.31 14.77 1.66
1001
38.96 15.92 1.43
67
(19.4)
26.97 15.41 2.44 29.06 16.68 2.16 31.09 17.85 1.92 33.14 19.06 1.68 35.59 20.85 1.46
63
(17.2)
24.98 18.04 2.43 26.95 19.58 2.15 28.84 20.96 1.92 30.75 22.40 1.70 33.06 24.69 1.49
57
(13.9)
22.33 21.88 2.41 24.13 23.80 2.14 25.84 25.48 1.92 27.58 27.24 1.71 29.92 29.92 1.51
80
(26.7)
72
(22.2)
744
29.51 15.35 2.44
801
31.74 16.60 2.15
842
33.93 17.76 1.91
887
36.15 18.96 1.66
1001
38.77 20.72 1.43
67
(19.4)
26.90 18.70 2.44 28.98 20.29 2.15 31.00 21.72 1.92 33.04 23.21 1.68 35.47 25.60 1.46
63
(17.2)
34.45 25.97 4.20 26.90 23.17 2.15 28.79 24.81 1.92 30.70 26.53 1.70 33.02 29.42 1.49
57
(13.9)
30.79 29.76 4.10 33.37 32.41 3.78 35.77 34.73 3.46 38.24 37.17 3.15 41.59 41.26 2.86
STAGE 1 - FCM4X60 ONLY
75
(23.9)
72
(22.2)
662
25.60 10.40 1.99
500
18.27 7.44 0.93
500
19.44 7.91 0.83
508
20.67 8.39 0.71
534
22.04 8.96 0.56
67
(19.4)
23.27 13.31 1.99 16.64 9.65 0.95 17.72 10.17 0.86 18.84 10.76 0.75 20.11 11.51 0.61
63
(17.2)
21.53 15.58 1.99 15.45 11.39 0.97 16.45 11.96 0.88 17.49 12.62 0.77 18.68 13.53 0.65
57
(13.9)
19.26 18.92 1.98 13.90 13.90 0.98 14.76 14.58 0.90 15.69 15.35 0.81 16.77 16.48 0.70
80
(26.7)
72
(22.2)
662
25.60 10.40 1.99
500
18.26 7.44 0.93
500
19.44 7.91 0.83
508
20.67 8.39 0.71
534
22.04 8.96 0.56
67
(19.4)
23.27 13.31 1.99 16.64 9.65 0.95 17.72 10.17 0.86 18.84 10.76 0.75 20.11 11.51 0.61
63
(17.2)
21.53 15.58 1.99 15.45 11.39 0.97 16.45 11.96 0.88 17.49 12.62 0.77 18.68 13.53 0.65
57
(13.9)
19.26 18.92 1.98 13.90 13.90 0.98 14.76 14.58 0.90 15.69 15.35 0.81 16.77 16.48 0.70
STAGE 1 - ALL OTHER COILS
75
(23.9)
72
(22.2)
662
25.60 10.40 1.99
457
17.95 7.29 0.93
482
19.30 7.84 0.83
508
20.67 8.39 0.71
534
22.04 8.96 0.56
67
(19.4)
23.27 13.31 1.99 16.36 9.31 0.95 17.59 10.02 0.86 18.84 10.76 0.75 20.11 11.51 0.61
63
(17.2)
21.53 15.58 1.99 15.18 10.89 0.97 16.33 11.74 0.88 17.49 12.62 0.77 18.68 13.53 0.65
57
(13.9)
19.26 18.92 1.98 13.59 13.23 0.98 14.63 14.27 0.90 15.69 15.35 0.81 16.77 16.48 0.70
80
(26.7)
72
(22.2)
662
25.60 10.40 1.99
457
17.95 7.29 0.93
482
19.30 7.84 0.83
508
20.67 8.39 0.71
534
22.04 8.96 0.56
67
(19.4)
23.27 13.31 1.99 16.36 9.31 0.95 17.59 10.02 0.86 18.84 10.76 0.75 20.11 11.51 0.61
63
(17.2)
21.53 15.58 1.99 15.18 10.89 0.97 16.33 11.74 0.88 17.49 12.62 0.77 18.68 13.53 0.65
57
(13.9)
19.26 18.92 1.98 13.59 13.23 0.98 14.63 14.27 0.90 15.69 15.35 0.81 16.77 16.48 0.70
Operation in this area is restricted to maintain reliable system operation and customer comfort. The system will default to the next available stage
Stage 5 - Compressor speed limited to stage four at 65 outdoor. Stage 1 - Compressor speed limited to stage two at 105 outdoor.
See additional notes on page 28