Installation Manual
441 01 3500 00 5
Specifications are subject to change without notice.
A190065
Fig. 3 -- Dimensional Drawing
Table 1 – Dimensions -- In. (mm)
FURNACE SIZE
A
CABINET
WIDTH
B
OUTLET WIDTH
C
TOP AND
BOTTOM FLUE
COLLAR
D
BOTTOM
INLET WIDTH
VENT
CONNECTION
SIZE
SHIP WT.
LB (KG)
0451712
17---1/2 (445) 15---7/8 (403) 11---9/16 (294) 16 (406) 4 (102) 118 (53.5)
0701412
14---3/16 (360) 12---9/16 (319) 9---5/16 (237) 12---11/16 (322) 4 (102) 118 (53.5)
0701716
17---1/2 (445) 15---7/8 (403) 11---9/16 (294) 16 (406) 4 (102) 126 (57.1)
0702120
21 (533) 19---3/8 (492) 13---5/16 (338) 19---1/2 (495) 4 (102) 147 (66.7)
0901716
17---1/2 (445) 15---7/8 (403) 11---9/16 (294) 16 (406) 4 (102) 134 (60.8)
0902120
21 (533) 19---3/8 (492) 13---5/16 (338) 19---1/2 (495) 4 (102) 153 (69.4)
1102120
21 (533) 19---3/8 (492) 13---5/16 (338) 19---1/2 (495) 4 (102) 156 (70.7)
1352422
24---1/2 (622) 22---7/8 (581) 15---1/16 (383) 23 (584) 4 (102)* 169 (76.6)
*135 and 155 size furnaces require a 5 or 6---in. (127 or 152 mm) vent. Use a vent adapter between fu r nace and vent stack. See Installation Instructions for
complete installation requirements.
4. If you touch ungrounded objects (and recharge your body
with static electricity), firmly touch a clean, unpainted
metal surface of the furnace again before touching control
or wires.
5. Use this procedure for installed and uninstalled (ungroun-
ded) furnaces.
6. Before removing a new control from its container, dis-
charge your body’s electrostatic charge to ground to pro-
tect the control from damage. If the control is to be in-
stalled in a furnace, follow items 1 through 4 before
bringing the control or yourself in contact with the fur-
nace. Put all used and new controls into containers before
touching ungrounded objects.
7. An ESD service kit (available from commercial sources)
mayalsobeusedtopreventESDdamage.
LOCATION
GENERAL
This multipoise furnace is shipped in packaged configuration.
Some assembly and modifications are required when used in any
of the four applications shown in Fig. 4.
NOTE: For high--altitude installations, the high--altitude
conversion kit MUST be installed at or above 5500 ft. (1676 M)
above sea level. Obtain high-- altitude conversion kit from your
area authorized distributor.