PRODUCT SPECIFICATIONS Split System Air Conditioner: HVA9
18 421 51 5800 02
Specifications subject to change without notice.
HVA937
DETAILED COOLING CAPACITIES
#
EFFICIENCY MODE CONTINUED
EDB
°F
(°C)
EVAP.
AIR
HVA937 / FCM4X60***L Efficiency Mode
Condenser Entering Air Temperature °F (°C)
115 (46.1) 105 (40.5) 95 (35) 85 (29.4) 75 (23.9) 65 (18.3)
EWB
°F (°C)
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
ID
SCFM
Capacity MBtuh
Total
Sys.
KW**
Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
STAGE 5
75
(23.9)
72
(22.2)
1050
32.70 13.63 3.49
1050
34.98 14.48 3.05
1050
37.03 15.26 2.59
1050
39.26 16.11 2.21
1050
41.44 16.95 1.86
1050
43.61 17.78 1.54
67
(19.4)
31.53 19.22 3.08 31.81 19.44 3.03 33.70 20.30 2.58 35.71 21.22 2.21 37.69 22.14 1.87 39.65 23.05 1.56
63
(17.2)
27.56 22.33 3.44 29.48 23.32 3.02 31.25 24.26 2.58 33.12 25.24 2.21 34.94 26.21 1.88 36.75 27.17 1.58
57
(13.9)
25.78 25.78 3.41 27.31 27.31 3.00 28.73 28.73 2.56 30.19 30.19 2.21 31.62 31.62 1.89 33.01 33.01 1.61
80
(26.7)
72
(22.2)
1050
32.58 18.47 3.49
1050
34.86 19.41 3.05
1050
36.91 20.26 2.59
1050
39.14 21.19 2.21
1050
41.32 22.11 1.86
1050
43.48 23.02 1.54
67
(19.4)
31.43 24.01 3.08 31.71 24.30 3.03 33.60 25.24 2.58 35.61 26.24 2.21 37.59 27.23 1.87 39.55 28.22 1.56
63
(17.2)
27.61 27.02 3.44 29.49 28.13 3.02 31.23 29.15 2.58 33.10 30.22 2.21 34.91 31.27 1.88 36.70 32.31 1.58
57
(13.9)
27.36 27.36 3.44 28.98 28.98 3.01 30.45 30.45 2.57 32.00 32.00 2.21 33.49 33.49 1.89 34.96 34.96 1.59
STAGE 3
75
(23.9)
72
(22.2)
900
22.96 9.72 2.41
900
24.70 10.37 2.11
900
26.36 10.99 1.76
900
28.08 11.65 1.50
900
29.77 12.29 1.25
900
31.45 12.93 1.03
67
(19.4)
20.81 13.49 2.42 22.39 14.22 2.13 23.90 14.93 1.79 25.43 15.65 1.54 26.95 16.37 1.30 28.46 17.09 1.08
63
(17.2)
19.24 16.44 2.42 20.68 17.23 2.14 22.09 18.01 1.80 23.50 18.79 1.56 24.89 19.57 1.34 26.28 20.35 1.13
57
(13.9)
18.34 18.34 2.42 19.54 19.54 2.15 20.70 20.70 1.82 21.85 21.85 1.58 22.98 22.98 1.37 24.10 24.10 1.17
80
(26.7)
72
(22.2)
900
22.86 13.49 2.41
900
24.60 14.23 2.11
900
26.26 14.93 1.76
900
27.98 15.67 1.50
900
29.67 16.39 1.25
900
31.35 17.12 1.03
67
(19.4)
20.74 17.22 2.42 22.31 18.03 2.13 23.83 18.82 1.79 25.36 19.62 1.54 26.87 20.42 1.30 28.38 21.22 1.08
63
(17.2)
19.57 19.57 2.42 20.83 20.83 2.14 22.16 21.83 1.80 23.54 22.72 1.56 24.92 23.58 1.33 26.29 24.45 1.12
57
(13.9)
19.53 19.53 2.42 20.79 20.79 2.14 22.01 22.01 1.80 23.22 23.22 1.56 24.42 24.42 1.34 25.59 25.59 1.14
STAGE 1
75
(23.9)
72
(22.2)
800
18.16 7.73 1.96
800
19.62 8.28 1.73
600
15.04 6.28 0.87
600
16.16 6.71 0.72
600
17.28 7.14 0.57
600
18.39 7.57 0.43
67
(19.4)
16.42 10.82 1.98 17.74 11.45 1.76 13.64 8.56 0.91 14.65 9.05 0.76 15.65 9.54 0.62 16.65 10.04 0.49
63
(17.2)
15.19 13.25 1.99 16.40 13.94 1.77 12.63 10.35 0.93 13.55 10.90 0.80 14.47 11.44 0.66 15.39 11.99 0.53
57
(13.9)
14.59 14.59 1.99 15.61 15.61 1.78 11.87 11.87 0.95 12.64 12.64 0.82 13.40 13.40 0.70 14.16 14.16 0.58
80
(26.7)
72
(22.2)
800
18.08 10.84 1.96
800
19.54 11.47 1.73
600
14.98 8.55 0.87
600
16.10 9.05 0.72
600
17.22 9.55 0.57
600
18.33 10.05 0.43
67
(19.4)
16.38 13.89 1.98 17.69 14.60 1.75 13.60 10.81 0.91 14.60 11.37 0.76 15.60 11.94 0.62 16.60 12.50 0.49
63
(17.2)
15.57 15.57 1.99 16.66 16.66 1.77 12.67 12.58 0.93 13.57 13.20 0.79 14.48 13.82 0.66 15.39 14.44 0.53
57
(13.9)
15.54 15.54 1.99 16.63 16.63 1.77 12.62 12.62 0.93 13.43 13.43 0.80 14.23 14.23 0.67 15.04 15.04 0.54
Operation in this area is restricted to maintain reliable system operation and customer comfort. The system will default to the next available stage
Stage 1 - Compressor speed limited to stage two at 105 and 115 outdoor.