Specifications

PRODUCT SPECIFICATIONS Fan Coils: FCM4X
496 51 4202 02 5
Specifications are subject to change without notice.
PHYSICAL DATA
MODEL FCM4X
SIZE 24 36 48 60
COIL
Refrigerant Metering Device R- 410A REFRIGERANT TXV
TXV Size 2Ton 3Ton 4Ton 5Ton
Configuration A Slope A A
Rows—Fins/In. 3 / 14.5
Face Area (Sq Ft) 3.46 3.46 5.93 7.42
MATCHES OUTDOOR UNIT SIZES
Nominal Cooling Tons 1.5, 2, 2.5, 3 2, 2.5, 3, 3.5 2.5, 3, 3.5, 4 3, 3.5, 4, 5
FAN
Air Discharge Upflow, Downflow, Horizontal
CFM/Ton (Nominal Clg/Htg) 350+
Motor HP (ECM) 1/2 1/2 1/2 3/4
Filter
21- 1/2- in (546 mm) x
16-3/8-in
(417 mm)
19-7/8-in
(505 mm)
19-7/8-in
(505 mm)
23- 5/16- in
(592 mm)
CABINET CONFIGURATION OPTIONS
1- piece 1- piece 1- piece Modular
PERFORMANCE DATA
AIRFLOW DELIVERY COOLING, HEATING, ELECTRIC HEATING MODES
The FCM4X fan coils with the Observert Communicating Wall
Control will provide airflow at a rate that is requested by the wall
control during air conditioning or heat pump heating (without
electric heat) modes. The nominal airflow for both heating and
cooling modes is 350 cfm/ton nominal size of the outdoor unit
installed. The airflow actually requested by the wall control is
modified by its internal algorithms for comfort or efficiency
concerns. Refer to the documentation for the wall control for
more information on how the wall control controls the fan coil.
Safe operation of electric heaters requires airflow delivery at or
above the minimum CFM for electric heater application listed in
the chart below. The fan coil will adjust its airflow delivery to
maintain safe airflow as operating mode and staging conditions
require.
FCM4X FAN COIL AIRFLOW DELIVERY CHART (CFM) ELECTRIC HEATING MODELS
MODEL FCM4X OUTDOOR UNIT CAPACITY BTUH
ELECTRIC HEATER kW RANGE
5 7-9 10 15 20 24- 25 30
24
EMERGENCY
18,000
24,000
30,000
36,000
625
625
650
800
975
625
625
725
875
975
675
675
775
875
975
775
900
925
1025
950
1125
1125
36
EMERGENCY
24,000
30,000
36,000
42,000
675
675
800
975
1125
700
875
875
975
1125
775
875
875
1025
1125
850
1100
1100
1150
1150
1050
1150
1150
1250
1350
48
EMERGENCY
30,000
36,000
42,000
48,000
675
800
975
1125
1305
700
875
975
1125
1305
775
875
1025
1125
1305
850
1100
1150
1150
1305
1050
1150
1250
1250
1350
1400
1500
1425
1600
60
EMERGENCY
36,000
42,000
48,000
60,000
1050
1050
1125
1300
1625
1050
1050
1125
1300
1625
1050
1100
1150
1300
1625
1050
1350
1350
1350
1625
1125
1350
1350
1500
1750
1750
1750
1750
1750
1750
1750
Note 1: Emergency - Air conditioner with electric heater application, or emergency heat.
Note 2: These airflows are minimum airflows as UL listed.
Note 3: Dashed entry indicates that the heater/fan coil/outdoor unit combination is not approved. Do not apply.