Integration Guide

Hardware Integration Guide
Rev 1.0 Nov 19 18 41113538
4. The AirPrime WP7611 may transmit simultaneously with other collocated
radio transmitters within a host device, provided the following conditions are
met:
· Each collocated radio transmitter has been certified by FCC/IC for mobile
application.
· At least 20 cm separation distance between the antennas of the collocated
transmitters and the user’s body must be maintained at all times.
· The radiated power of a collocated transmitter must not exceed the EIRP
limit stipulated in
Table 5-2.
5. A label must be affixed to the outside of the end product into which the
AirPrime WP7611 is incorporated, with a statement similar to the following:
This device contains FCC ID: N7NWP76B/ IC:2417C-WP76B.
6. A user manual with the end product must clearly indicate the operating
requirements and conditions that must be observed to ensure compliance
with current FCC/IC RF exposure guidelines.
The end product with an embedded AirPrime WP7611 may also need to pass the
FCC Part 15 unintentional emission testing requirements and be properly
authorized per FCC Part 15.
Note: If this module is intended for use in a portable device, you are responsible for
separate approval to satisfy the SAR requirements of FCC Part 2.1093 and IC RSS-102.
Table 5-2: Collocated Radio Transmitter Specifications
Device Technology Frequency (MHz) EIRP Limit (dBm)
Collocated
transmitters
a
a. Valid collocated transmitter combinations: WLAN+BT; WiMAX+BT.
(WLAN+WiMAX+BT is not permitted.)
WLAN
2400–2500 25
5150–5850 27
WiMAX
2300–2400 25
2500–2700 25
3300–3800 25
BT 2400–2500 15