User's Manual

TIME OUT DURATION
The time-out duration is how long a channel can be held open (keyed on) for a retransmission.
An inadvertent or intentional “key and hold” action without any voice communication will not
disable the channel because of this feature. The time-out duration can be up set from 1 second to
99 seconds 1 second intervals. The time-out duration can be disabled by setting it to 00, when
disabled, the channel will key continuously with the presence of a received signal.
SETTING A TIME-OUT TIME
To set a time-out time, click on the text box “Time Out Timer” and enter the desired time-out
time up to 99 seconds then click “Send Button” next to the box. To verify the setting, click on
the “Read Button” and the display will be updated with the channel setting.
MODE SETTING
The channel mode may be set to either INHIBIT, CONTINUOUS, CARRIER DETECT or
optional TONE DETECT. In the Inhibit mode, the channel is off and will not key on. In the
50289-BAM-8-800
- 7 -