User`s guide

4 - 12 Aironet Wireless Client
The Autotest procedure can be used to help determine the placement of
repeater units. For example, at each prospective location, an installer
could cycle the power on the unit and watch the indicator displays for
the results of the link test. As the test begins to fail, the installer could
determine the radio range to the infrastructure and adjust the location
accordingly.
Continuously Running a Link Test (Continuous)
The continuous option is used to continuously repeat the link tests. If
the value for the parameter is zero the tests are not repeated; otherwise,
the value determines the delay (in seconds) between tests.
Table 4.1 - Auto Link Test Display Patterns
Radio Status
Ethernet
or
Serial
% of Packets Lost
Quality
Green Green Green 0-2 Excellent
Green Green Amber 3-5 Very Good
Green Green Off 6-25 Good
Green Amber Off 26-50 Satisfactory
Amber Off Off 51-75 Fair
Red Off Off 76-100 Poor
UCE.BK Page 12 Wednesday, February 10, 1999 12:10 PM