User`s guide

3 - 4 Aironet Wireless Client
è To Back Up Configurations:
NOTE: Commands may vary depending on the communications
program used.
1. In the terminal emulation program, set Save to File to “On”.
2. Select Configuration from the Main Menu then select Dump.
The following message appears:
Enter one of [all, non-default, distributable]:
n All: The entire configuration will be displayed.
n Non-default: Only the configuration options that are different
from the original default settings will be displayed.
n Distributable: Only the configuration options that are not con-
sidered unique to this unit are displayed. You may use the “diag-
nostics load distribute” command to send this configuration to
other units in the infrastructure.
3. Enter one of [standard, encoded] :
n Standard: The configuration is displayed in normal readable
text form.
n Encoded: The configuration is displayed with each configura-
tion command replaced by a unique number. This type of config-
uration is the best to save since the number will never change
over the life of the product. Text may change or move as more
items are added to the menus. The configuration commands will
now appear on the screen.