User`s guide

11 - 12 Aironet Wireless Client
Distributing Firmware or Configuration (Distribute)
Use the distribute option to send the firmware or configuration from one
Aironet Wireless Client to all other Aironet Wireless Clients on the
infrastructure. By using the distribute option the time needed to perform
firmware upgrades or make global changes to the configuration is greatly
decreased.
Once a new version of the firmware has been loaded into a single Airo-
net Wireless Client, (using Ftp or Bootp) or the configuration has
changed, use the distribute option to upgrade all other units.
If you are distributing a configuration, examine the parts of the unit’s
configuration that will be distributed by executing the command “config-
uration dump distributable standard”.
The control option controls how the remote units respond to a request to
send a configuration or firmware.
n None: The unit will never respond and cannot be loaded by another
unit using the distribute command.
n Any: The unit will always respond. It is up to the distributing unit to
determine whether to load the local unit.
n Newer: The unit will only respond if the version of firmware being
distributed has a larger version number than the code currently run-
ning. This selection only applies to firmware downloads.
n None of the Above: A password that must be entered by the operator
of the unit doing the distribution. The local unit will not respond to
any distributions that do not supply this password.
If the distribute is password protected, only those units that have the
same password configured in the control parameter will accept the dis-
tribution. The units can be protected from unwanted loads. The pass-
word may also be used to divide the units into code load groups such
that the loads to one group will not affect the other groups.