User`s guide

11 - 10 Aironet Wireless Client
4. Select the password option and type the password associated with
the username.
If downloading from another Aironet Wireless Client, the login
password value must match the console write privilege password on
the remote Aironet Wireless Client.
5. Select the filename option and type the name of the firmware file you
are retrieving (including drive and directory), then press ENTER.
If downloading from another Aironet Wireless Client, the filename
option must have a value even though the value is not used by the
remote Aironet Wireless Client.
6. Select the get option.
The unit will begin an FTP session to the host PC, retrieve the file,
program the flash memory, and reboot. A message will appear:
Uploading a New Firmware Version (Put)
Use the put option to upload (send) a copy of the currently running firm-
ware to another system. If the system is a:
n PC or host: A copy of the firmware will be stored on the system’s
disk, possibly for downloading to other units later.
n Aironet Wireless Client: The remote Aironet Wireless Client will
flash the new code and begin running it immediately. You can use
one Aironet Wireless Client to upgrade another Aironet Wireless
Client.
220 sun_host FTP server (SunOS 4.1) ready.
230 User sysop logged in.
200 Type set to I.
200 PORT command successful.
150 Binary data connection for apv33.img (163056 bytes).
226 Binary Transfer complete.
221 Goodbye.
FTP: received 161056 bytes in 00:00:10; 15 Kbytes/s transfer rate
rebooting unit.
UCE.BK Page 10 Wednesday, February 10, 1999 12:10 PM