User`s guide
11 - 8 Aironet Wireless Client
When the unit powers up, the boot block checks the integrity of the
application code. If it is valid, the boot block will execute the new firm-
ware. If it is invalid, the boot block will display an error message on the
Console and the firmware will need to be reloaded.
The only time you should receive an invalid application code is when
the flash memory device fails or the power is interrupted while the flash
memory is in the process of being programmed.
Downloading or Uploading using the File Transfer Protocol (Ftp)
Use the FTP option to download or upload firmware. The Aironet Wire-
less Client can be an FTP client or FTP server. To upload or download
firmware you can initiate a connection from:
n The Aironet Wireless Client console to a remote PC or host and
retrieve a new version of the firmware.
n The Aironet Wireless Client console to a remote PC or host and send
a copy of the running firmware.
n One Aironet Wireless Client console to another allowing units to
send or receive firmware running locally.
n A PC or host system to the Aironet Wireless Client and send a new
firmware version.
NOTE: Before you download or upload new code versions, make sure you
have set the IP address on all units involved.
UCE.BK Page 8 Wednesday, February 10, 1999 12:10 PM