User`s guide
10 - 10 Aironet Wireless Client
2. You will be prompted for the statistics category. Enter the number or
the short form. The short form is used to store the command in the
configuration.
3. Type a category number or the short form and press ENTER.
4. Choose the particular statistics that you wish to change. If any of the
statistics already have an alarm associated, the current setting is dis-
played after the name.
Enter an action, one of [off, any, rate]:
5. Enter an action.
n Off: Turns off any alarms based on the statistics value.
n Any: An alarm will be generated if the statistics change value.
n Rate: Prompts for a rate per second change. If the statistic value
changes faster than this rate, an alarm is produced.
Radio
Receive Transmit
1 rpa Packets 5 tpa Packets
2 rby Bytes 6 tby Bytes
3 rfi Filtered 7 ter Errors
4 rer Errors
Enter one of [a number from 1 to 7, a short form]
UCE.BK Page 10 Wednesday, February 10, 1999 12:10 PM