User`s guide

10 - 4 Aironet Wireless Client
Unable to locate IP address “ip address”
The unit was trying to send a packet to an IP address without knowing
the hardware node ID. When this occurs, the unit will use the ARP pro-
tocol to try to determine the proper address. This log is produced if there
was no answer to the ARP request. Usually the unit is trying to find the
destination for the SNMP traps.
Severe Error Logs
Ethernet cabling problem
If no traffic has been sent or received on the Ethernet cable in the last
10 seconds, the unit will send a packet to itself to test the connection. If
the transmission succeeds, the timer is reset. If it fails, this log is pro-
duced and traffic for the connection will be discarded until the test suc-
ceeds.
Configuration is too large to save
The number of commands in the configuration is too large for the avail-
able non-volatile memory. This may be caused by too many non-volatile
entries in the association table.
Could not program the flash memory
An error occurred when trying to program a new version of the firmware
into flash memory. The unit must be serviced.
Lost our association, max radio retries
The unit, configured as a repeater, lost communications with its parent
node after trying to send a packet the maximum number of times. The
unit will try to re-associate. The problem may be a parent Aironet Wire-
less Client failure. All local associations will be dropped.
UCE.BK Page 4 Wednesday, February 10, 1999 12:10 PM