5 - 6 Ethernet or Token Ring Bridge
The Token Ring number and the radio ring numbers should be assigned
by your network administrator since each ring in your infrastructure
must be assigned a unique number.
Once these have been determined, all units must be configured with the
number of the Token Ring to which they are attached. The root unit must
also be configured with the virtual radio ring number. It will inform the
repeater units of the radio ring number when they associate to the root.
The root unit is also responsible for automatically assigning Bridge
numbers to itself and each repeater unit.
Using the Token Ring Extended Menu
Setting the Size of a Bridge Number (Partition) Token Ring Only
This option only appears if the Token Ring Bridge is in source route
mode. In the routing information field of a packet header, the ring and
Bridge numbers are packed into 16 bit integers. This option determines
how many of the 16 bits are used for the Bridge number portion. The
default value of 4 allows up to 15 Bridges to be connected to the same
set of rings (zero is not an option).
Typically, this parameter is not changed and should only be changed
after consulting with your network administrator.
Configuration Token Ring Extended Menu
Option Value Description
1 - Partition [ 4 ] - Number of bits in bridge numbers
2 - Earlyrls [ 18 ] - Maximum route field length
3 - Sap [ aa ] - Set control frame SAPs