User`s guide

13 - 6 Ethernet or Token Ring Bridge
Loading New Code Versions (Load)
The Ethernet or Token Ring Bridge code is stored in a flash memory
chip inside the unit. Use the load option to load new code versions of
the Ethernet or Token Ring Bridge’s firmware and save it to flash mem-
ory.
To load new versions of the firmware, the code must be loaded into main
memory first, then programmed into the flash memory. The unit will
reboot using the new firmware. The flash memory will retain the new
version even if the power is disconnected.
The new firmware can be downloaded into the unit using:
n FTP: Load the new firmware into a single unit using either the Xmo-
dem or FTP protocols. Then use the FTP protocol to upload (send)
the code running in the local unit to other remote units on the infra-
structure.
n Distribute: Load the new firmware into a single unit using either
the Xmodem or FTP protocols. Then use the distribute option to
simultaneously load all of the other units on the infrastructure,
whether they are connected wirelessly or via the wired infrastruc-
ture.
n Bootp: Load the new firmware and configuration revisions into the
units each time they power up.
When you select the load option, the Diagnostics Load Menu appears:
Diagnostics Load Menu BR105E_22ef0a
Option Value Description
1 - Xmodem - Xmodem load from serial port
2 - Crc-xmodem - Xmodem-CRC load from serial port
3 - Ftp [ menu ] - Load using FTP
4 - Distribute [ menu ] - Distribute the firmware
5 - Bootp/DHCP [ on ] - Use BOOTP/DHCP on startup
6 - Class [BRE105E] - DHCP class id
Enter an option number or name, "=" main menu, <ESC> previous menu
>