User`s guide

9 - 6 Ethernet or Token Ring Bridge
n Frame copy error: The Token Ring adapter has received a frame
addressed to itself that has been marked as already copied off the
ring. This could be due to a duplicate address on the ring or a possi-
ble line hit.
n Token error: The Token Ring adapter has either not received a
token in the required time or has received an invalid token.
n DMA bus error: The number or bus errors that occurred during
DMA transfers between main memory and the Token Ring adapter’s
memory
n DMA parity error: The number of parity error that occurred during
DMA transfers between main memory and the Token Ring adapter’s
memory.
n Signal loss: The Token Ring adapter has detected a loss of signal on
the ring.
n Hard error: The Token Ring adapter has transmitted or received
beacon frames to or from the ring.
n Soft error: The Token Ring adapter has transmitted a report error
MAC frame.
n Transmit beacon: The Token Ring adapter has transmitted beacon
frames to the ring.
n Lobe wire fault: The Token Ring adapter has detected an open or
short circuit between the adapter and the wiring concentrator.
n Auto removal error: The Token Ring adapter has failed the lobe
wrap test due to a beacon auto-removal process.
n Remove received: The Token Ring adapter has received a remove
ring node MAC frame and has deinserted from the ring.
n Ring recovery error: The Token Ring adapter has received a claim
token MAC frame from the ring.
n Packet too long: The Token Ring adapter has received a packet with
a length exceeding the maximum length allowed.