Airmux-200 Ver. 1.750 Configuration via Telnet 4-31
Table 4-4. Telnet Commands
Command Explanation
display inventory Displays ODU product name, Name, Location, hardware and
software revisions, uptime, MAC address, IDU product name,
IDU software and hardware revisions
display management Displays IP, Subnet, Gateway, Traps table
display link Displays State, SSID, Channel BW, RSS, TSL, Frequency/ACS,
DFS, Rate/ARA, Distance
display Ethernet Displays Bridge Mode, Aging time, Port table (State, Status and
action)
display tdm Displays Clock Mode, Master Clock Mode, Current Clock,
Quality[1], TDM table (Line status, Error Blocks)
display ntp Displays Time, Server and Offset
set ip <ipaddr> <subnetMask>
<gateway>
Set the ODU IP address, subnet mask and gateway
The user must reset the ODU after the command completion
set trap <index:1-10> <ipaddr>
<port:0-65535>
Set a specific trap from the traps table (set trap 3 10.0.0.133
162)
set readpw <oldpasswd> <passwd> Set the read access password (read community)
set writepw <oldpasswd> <passwd> Set the read-write access password (read-write community)
set trappw <oldpasswd> <passwd> Set the trap community string
set buzzer <mode:0=OFF,1 =ON> Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between minimal TX
power, and maximal TX power>
Set the ODU transmit power. If a wrong value is entered, both
min and max values shall be displayed in the error reply
set bridge <mode:0=Bridging OFF,
1= Bridging ON >
Set the ODU bridge mode (0 – off, 1 – on)
reboot Reset both the IDU and the ODU. The user shall be prompt
that the command will reset the card and that he has to
reconnect the telnet session after TBD seconds.
help Displays the available commands
Figure 4-22
shows the available Telnet commands via the Help command.