Specifications

Chapter 4 Configuration Installation and Operation Manual
4-12 Editing the Configuration Parameters Airmux-200 Ver. 1.750
Click Finish to complete the configuration wizard.
The Main screen is displayed.
4.5 Editing the Configuration Parameters
You can edit the configuration parameters for each site individually without
running a wizard.
From the Configuration dialog box, (see
Figure 4-10
) the following functions are
available by selecting the items on the left of the dialog box:
System Edit the contact person and location details. View the system
details
Air Interface Change the transmit power
Inventory View the hardware and software inventory.
Management Configure the IP address, Subnet Mask, Default Gateway, and
the Trap Destination.
Security Change the Community Values and the Link Password
Date and Time Set the date and time of the server and of the system.
Advanced Configure the Bridge, define the LAN connection and set the
external alarm inputs.
From the Configuration dialog box, the following functions are available by
clicking the buttons at the top of the dialog box:
Backup Save a backup.ini file with the current configuration.
Restore Load the backup.ini file created by the backup.
Installation Mode Return to Installation Mode for the entire link.
Selecting the Mute check box before clicking the Install Mode
button mutes the Beeper.
Mute Mutes the Beeper at startup. Reactivate the beeper during
alignment.
To edit the Configuration Parameters:
1. Click Configuration from the main menu.
2. Select which site to configure.
The Configuration dialog box opens. (See