Specifications

Chapter 3 Operation Installation and Operation Manual
3-4 Managing Airmux-200 Airmux-200 Ver. 1.750
3.3 Default Settings
Table 3-5
lists the default settings of the Airmux-200 configuration parameters.
Table 3-5. Default Settings
Parameter Default Value
ODU IP Address 10.0.0.120
Subnet Mask 255.0.0.0
SSID
Frequency First Frequency in the range
Rate Adaptive
Services Ethernet
Ethernet Configuration Auto Detect
Bridge Hub Mode.
Aging time = 300 sec
Community values Read-write – netman
Local – public-bru1
Remote – public-bru4097
3.4 Managing Airmux-200
Before starting a management session, make sure that a communication link
between local and remote units exists. The Link Status indication bar in the
middle of the Main menu must be green and the
Radio Link - Sync
message must
appear in the event log (see
Figure 3-4
).