Specifications

Installation and Operation Manual Chapter 2 Installation and Setup
Airmux-200 Ver. 1.750 Installing the Link 2-21
3. Click Next.
If TDM services were selected, then the TDM parameters dialog box
appears, (see
Figure 2-18
).
4. The optimum transmission rate for the selected services is evaluated.
Table 2-1
shows the rates used by Airmux-200.
Airmux-200-L versions do not have TDM services, they operate at a default rate
of 2 Mbps.
If Ethernet Only was selected, then the Finish screen appears
(see
Figure 2-20
) showing a summary of the link configuration, the
alignment is complete.
Table 2-1. Rates Per Bandwidth
Modulation/FEC 5 MHz 10 MHz 20 MHz
BPSK / ¾ 2.25 Mbps 4.5 Mbps 9 Mbps
QPSK / ½ 3 Mbps 6 Mbps 12 Mbps
QPSK / ¾ 4.5 Mbps 9 Mbps 18 Mbps
16QAM / ½ 6 Mbps 12 Mbps 24 Mbps
16QAM / ¾ 9 Mbps 18 Mbps 36 Mbps
64QAM /
2
/
3
12 Mbps 24 Mbps 48 Mbps
64QAM / ¾ 13.5 Mbps 27 Mbps
Setting the Clock Configuration
If TDM services are selected then the TDM parameters dialog box appears. (TDM
is not relevant in Airmux-200-L versions.)
The TDM Parameters dialog box contains five working modes. Select the
appropriate clock mode according to your application. Choosing one of these
modes sets the TDM clock behavior on both sides of the link. The user equipment
must be configured as described
Table 2-2
.