Specifications

Chapter 1 Introduction Installation and Operation Manual
1-10 Technical Specifications Airmux-200 Ver. 1.750
SERVICE (green/red)
E1/T1 signal status
Power
Source
IDU: 100–240 VAC via external AC/DC converter
IDU-E: 100–240 VAC via AC cable
-48 VDC (-42 to –60 VDC), 24 VDC
Power Received by
the ODU
-48 VDC
Power Consumption
ODU plus IDU – 10W max
ODU plus IDU-E – 14W max
Connector
IDU 2-pin
IDU-E AC – 3-pin IEC connector
DC – 3-pin terminal block
Connector
DB-9 female
Alarm
Connector
Electrical
Characteristics
Dry Contact, 30V/2A
Max input current, 0.01A at 0.5W (R=5K)
Physical
Outdoor Unit (ODU and O-PoE) ODU with integrated
antenna
Height
24.5 cm (9.3 in) 30.5 cm (12 in)
Width
13.5 cm (5.13 in) 30.5 cm (12 in)
Depth
4.0 cm (1.57 in) 5.8 cm (2.3 in)
Weight
1.0 kg (2.2 lb) 1.5 kg (3.3 lb)
Indoor Unit IDU IDU-E
Height
4.5 cm (1.7 in) 1U 4.5 cm (1.7 in) 1U
Width
23.5 cm (9.3 in) 29 cm (11.5 in)
Depth
16.5 cm (6.7 in) 43 cm (17.7 in)
Weight
0.5 kg (1.1 lb) 1.5 kg (3.3 lb)
Environment
Outdoor Unit (ODU and O-PoE)
Enclosure
All-weather case
Temperature
-35° to 60°C (-31° to 140°F)
Indoor Unit (IDU and IDU-E)
Temperature
-0° to 50°C (32° to 122°F)
Humidity
Up to 90%, non-condensing