Specifications

Appendix F Hub Site Synchronization Installation and Operation Manual
F-6 HSS Link Configuration Airmux-200 Ver. 1.750
Table F-2. External Pulse Status
Status Description Text Color
Not Detected Sync pulses not detected Green
Generating Unit is HSM and is generating RFP pulses Green
Generating and Detected Unit is HSM and generating RFP pulses
and is also receiving pulses from another
unit. Incorrect configuration.
Red
Generating and Improper
Detected
Unit is HSM and generating RFP pulses
and is also receiving incorrect pulses from
another unit. Incorrect configuration.
Red
Detected HSC detecting pulses Green
Improper Detected Incorrect RFP and BW configuration Red
Multiple Sources Detected More than one HSM generating pulses.
Incorrect configuration.
Red
To configure the Operational States of the hub site unit
1. Click the Enabled check box
2. Click the Configure button
The Hub Site Configuration dialog box with the current status of the
ODUs is displayed.
3. Select the type of unit configuration from the drop-down list. Because only
the relevant options are displayed according to the hardware configuration of
each unit, usually the remote site will have only the Independent Unit option
available.
4. Select the appropriate RFP radio button. Some RFP options may be disabled
depending on the BW previously selected.
Take care to avoid incorrect configuration of bandwidth, RFP or to set multiple
Hub Sync Masters, as system interference can occur. Airmux-200 gives error
messages and tool tips if the system is configured with mismatches.
Note