Specifications

Appendix F Hub Site Synchronization Installation and Operation Manual
F-4 Radio Frame Pattern Table Airmux-200 Ver. 1.750
The remote ODUs that are not located at the hub site, are called Independent
Units and do not require HSS hardware.
Figure F-4. HSS Typical Application
F.4 Radio Frame Pattern Table
The synchronization pulse is termed Radio Frame Pattern (RFP). Four RFP pulses
are available. The RFP is selected depending on the type of services that the
complete system is to provide (see
Table F-1
.) Select the RFP that gives you the
Best Fit for the system services and select the Channel Bandwidth accordingly.
The RFP must be the same for each link within the collocated system.
Table F-1. Radio Frame Pattern Table
Channel Bandwidth
20 MHz 10 MHz 5 MHz
RFP TDM & EDO TDM EDO TDM EDO
A Best fit Non Optimal Not Available
B Not Available Best fit Non Optimal Best fit Non Optimal
C Not Available Not Available Best fit Not Available Non Optimal
D Not Available Not Available Not Available Best fit
Note