Specifications
Chapter 5 Diagnostics and Troubleshooting Installation and Operation Manual
5-10 Link Compatibility Airmux-200 Ver. 1.750
5.6 Link Compatibility
Airmux-200 indicates the version compatibility via software traps. As new
hardware is added to existing networks compatibility issues may arise. An
incompatibility issue is indicated to the user via a change of color of the Link
Status box on the Main Menu screen. Trap messages in the Event Log indicate the
problems or limitations and suggest upgrades when appropriate.
The following Link Status messages are given:
fullCompatibility - different software versions that are fully compatible. Message
indicates that upgrade is available.
restrictedCompatibility - different software versions that operate correctly.
However, new features are not supported
softwareUpgradeRequired - different software versions with limited operation.
The link will operate as Ethernet only; a full service will not be available. The
message is software upgrade required.
versionsIncompatibility - different software versions that are not compatible.
User needs to perform local upgrades.
Table 5-5. Link Compatibility Trap Messages
Link State Link State
Text
Link Status
Color
Site Description Site
Desc.
Color
Link Status
Color
fullCompatibility Active Green SW
Upgrade Available
Yellow Green
restrictedCompatibility Active - SW
Version
mismatch
Magenta
(Same as
authentication
error)
SW Upgrade
Recommended
Yellow Magenta (Same
as authentication
error)
softwareUpgradeRequired Active – SW
Upgrade
Required
Brown (Major) SW Upgrade
Required
Yellow Brown (Major)
versionsIncompatibility Not Active -
SW Upgrade
Required
Red Local SW Upgrade
Required
Yellow Red