Specifications

AIRMAR
®
PB100 WeatherStation Technical Manual revision 1.007
40
_NMEA 0183 RECEIVED SENTENCE_
$PAMTC,EN
Summary
Enable or disable the periodic transmission of individual standard NMEA 0183
sentences, and specify their rate of transmission.
Syntax
One of the following forms:
$PAMTC,EN,<2>,<3>,<4>*hh<CR><LF>
$PAMTC,EN,S*hh<CR><LF>
$PAMTC,EN,L*hh<CR><LF>
$PAMTC,EN,LD*hh<CR><LF>
$PAMTC,EN,Q*hh<CR><LF>
Fields
<2>
The identifier ALL, or one of the following sentence ID’s:
Model PB100:
GGA, GLL, GSA, GSV, HDG, MDA, MWD, MWVR,
MWVT, RMC, VTG, VWR, VWT, XDR, XDRA, XDRB,
ZDA
Model LB100:
MDA, MWD, MWVR, MWVT, VWR, VWT, XDR, XDRA
<3>
If field <2> is the ALL identifier, then
0 = disable transmission of all sentences
1 = enable transmission of all sentences.
Otherwise,
0 = disable transmission of the specified sentence
1 = enable transmission of the specified sentence
<4>
The amount of time between successive transmissions of the specified
sentence, in tenths of a second. For example, if field <4> contains the
value 5, this specifies an interval of 0.5 seconds between successive
transmissions of the specified sentence.
If field <2> is the ALL identifier, then field <4> specifies the
transmission interval for all sentences.