User Manual

2 3
AIRMAN” MOST ADVANCED GENERATOR
Applicable for every field and jobsite!!
Further environment friendly!!
SDG-F series
10.5 220kVA
Unlike separate fuel bund and generator oil bund, Airman’s fully bunded with extended tank minimize any potential of rain water
penetration into the bund and minimize the maintenance work required.
Point
PointPoint
Separate oil bund is not required
No separate oil bund is required for the generator as well as
the additional fuel tank.
Additional fuel tank is not required
No potential fuel leakage along the interconnecting pipes.
Rain water ingress is minimized
Rainwater will not be collected like traditional oil bund as it is
fully integrated within the enclosure package.
Complete package is fully transportable
Without separate fuel tank and oil bund, the fully integrated
generator with long-range tank and integrated bund is fully
transportable as one package.
Convention package
Engine generator
Oil bund
( for generator )
Additional fuel tank
Fuel bund
( for additional fuel tank )
Fuel line
●Prevention of rain penetration
●Facilitated maintenance
●Prevention of rain infiltration
Prevention of water and oil leak
Insert type seal which is usually used for
automobile is adopted so that rain
penetration can be avoided.
●Warning indicator
The warning lamp on the panel goes
on when oil /
water is filled in
the oil bund.
For the series from SDG13 to SDG60,
the portions of oil fence are formed by
bending so that welding work is
minimized. Further, air tight welding
work is continuously performed on
welded portions.
Double wall steel fuel tanks have
110% fluid capacity containment.
Air inlet port is specially designed to
increase intake air and to reduce the
suction pressure inside to minimize the
potential rain water penetration.
Oil fence can be
easily removed and
reinstalled by
removing the stud
bolts ( 4 8 pieces ).
Fuel tank is
provided with
lifting hooks as
standard.
Patent
Utility model
A big capacity fuel tank equipped as a standard one enables long continuous operation without any additional fuel tank provided.
Continuous operation
SDG13S-F
SDG25S-F
SDG45S-F
SDG60S-F
SDG100S-F
SDG125S-F
SDG150S-F
0 24(1day) 48(2day) 72(3day)
at 50% load
at 75% load
hr
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
SDG220S-F
50Hz
60Hz
Point
PointPoint
Environmental
Containment Onsite Type
Continuous operation for the time from
1 day & half 3 days
Specially designed construction for
prevention of rain penetration
Fuel tankPortion of oil bund
Oil bund and Oil Fence are same meaning